BION CY-E517C Skrócona instrukcja obsługi

Przeglądaj online lub pobierz pdf Skrócona instrukcja obsługi dla Akcesoria rowerowe BION CY-E517C. BION CY-E517C 2 stron.

BION CY-E517C Skrócona instrukcja obsługi
English
E500 Series
E512, E516T, E518T, E517C, E520C, E523A, E526AC
E512, E516, E518T, E523A
or
CY-E500
E517C, E520C, E526AC
Cadence & Speed Sensor
CY-E500
(Black)
Stabling Pads
Black:Cadence Magnet
Mounting
Cadence Magnet
Speed Magnet
White:Sensor Mounting
Bracket
Cycle Computer
Cycle Computer
Bracket
Bracket
Rubber
Rubber
(1)
(2)
Use the rubber to tighten the bracket to the handlebar or stem with the nylon ties.
Place the cycle computer on the bracket and secure it in clockwise.
E512, E516, E518T, E523A
Check the position of the front fork to find the suitable point to attach the speed sensor.
The distance between cycle computer & the speed sensor would be with 60 cm.
How to mount the Magnet
Screw
Sensor Point
Magnet
(Magnet)
(5)
(6)
Secure the Speed Magnet on the spoke of the front wheel with screw.
Make sure the magnet side faces the speed sensor zone.
The maximum distance between the speed sensor and the magnet on the spoke is 5 mm.
Once above items in the right position, the user may go for a ride.
Note:Please make sure everything has been setup correctly before riding the bicycle.
Installing the Cadence & Speed Sensor
Cadence Sensor
Speed Sensor
Stabling Pads
Nylon Ties
(4)
(White)
Mount the sensor on top of the left chain stay with long nylon ties, make sure the cadence side face
the front and speed side face the back. The distance between the sensor and the cycle computer
would approximately be 150 cm.
*NOTE:
1. The stabling pad has to be precisely
secured under the sensor.
2. Nylon ties have to be exactly and solidly bond
on the stabling pad.
3. Without proper bind, cadence sensor may be
crashed by the spoke of back freewheel.
How to mount the Magnet
(White)
Screw
Cadence Magnet
Speed Magnet
Stabling Pads
(Black)
(6)
(7)
Secure the Speed Magnet on the spoke of the back
wheel with screw. Make sure the magnet side faces the
speed sensor zone.The maximum distance between the
speed sensor and the magnet on the spoke is 5 mm.
Nylon
Ties
Secure the Cadence Magnet on the inner side of crank
and make sure the magnet side faces the cadence sensor
zone. Please use black stabling pad for cadence magnet
mounting. The maximum distance between the cadence
sensor and the magnet on the crank is 5 mm.
Once above items are in the right position, the user
may go for a ride.
Note:
Initial flashing green light indicates the sensor
detected magnet signals normally.
Please make sure everything has been setup
correctly before riding the bicycle.
Wheel Circumference
To get the accurate result, the wheel size should be
correct Mark the symbol on the tire and ride one
circle. Then measure the length between two points
to get the circumference. Or the user can also get
wheel circumference by the following equation:
Circumference(mm) = 2 x 3.14 x R(inch) x 2.54(1 inch=2.54 cm)
R=Radius in centimeter
The user can refer the "wheel size chart" for the wheel size
The cycle computer main display and Key function
E516T, E518T, E523A
Temperature
(Option CY-E516T, E518T)
E512
Sensor Point
(Sensor)
1~5mm
Press Mode key shortly to change mode.
(Clock)
(Trip Time)
(Average Speed)
(Max Speed)
E517C, E520C, E526AC
(Trip Distance)
(Daily Distance)
(5)
(Except E512)
(Total Distance Bike1)
(Except E512, E517C)
(Total Distance Bike2)
(Except E512, E517C)
(Total ODO)
In clock mode
Press
and hold "SET" key
for 3 seconds to go
setting clock.
Press "SET" key once
to adjust 12/24 hours.
Press "MODE" key to adjust time (hour, minute and second).
M
Adjustable
Hold "MODE" key for 3 seconds to go back to Clock Mode once the setting is finished.
TM MODE (Trip Time Mode)
Trip Timer would operate automatically when the bike is in motion.
How to reset all data (Kcal, TM, AVS, MXS, DST)
Press and hold "SET" key for 3 seconds,all exercises results in displayer will return to
zero, except odometer.
1~5mm
Note: If trip time runs over 30 hours, the display will repeatedly flash for 5 seconds and return to zero.
Green light
Speed
sensor
S
Cadence sensor
AVS MODE (Average Speed Mode)
The average speed
from the beginning
onwards.
(Except E512, E517C)
1
The odo accumulated
from bike 1
E517C, E520C, E526AC
Note:Odometer mode will return to zero after changing new battery.
Under ODO Mode, press "SET" key for 3 seconds to go to setting.
Press "MODE" key to go to temperature scale setting, Press "SET" key to select ℃or ℉.
S
(Average Cadence)
(Option in E517C, E520C, E526AC)
(Max Cadence)
(Option in E517C, E520C, E526AC)
M>3SEC
(Option in E523A, E526AC)
(Option in E523A, E526AC)
(Option in E523A, E526AC)
(Option in E523A, E526AC)
A. CAD (Average Cadence Mode)
(Option in E523A, E526AC)
(Option in E517C, E520C, E526AC)
(Option in E523A, E526AC)
Average cadence (pedals
AUTO SCAN
revolution per minute)
(Except E512, E516T)
from the beginning
onwards.
S
S>3sec
T. CLIMB MODE (Trip Climb Mode)
It indicates the current climbing value for the trip.
How to clear the climbing value
Under the T. CLIMB mode, press "SET" for 3 seconds to clear the data.
The display will show CLEAR and automatically return to zero after 3 seconds
S
M
T. ALT MODE (Total Altitude Mode)
It displays the total altitude value of bike1 + bike2
How to adjust actual altitude
Under T. ALT. mode, press "SET" key for 3 seconds to go to altitude setting.
Input the actual altitude data by pressing "SET" key.
Press "MODE" key to go to home altitude setting,
Input the home altitude data by pressing "SET" key.
Press "MODE" key to go to altitude bike1 setting,
Input the altitude bike1 data by pressing "SET" key.
Press "MODE" key for 3 seconds back to T. ALT. Mode.
S>3SEC
MXS MODE (Maximum Speed Mode)
M>3sec
The maximum speed
from the beginning
onwards.
(Option in E523A, E526AC)
Home Setting
It features and indicates the actual altitude of your start location.
In any mode, press and hold both "SET" key and "MODE" key for 6 seconds to automatically set
(Except E512)
default data of altitude.Note: keep pressing and hold both "SET" key and "MODE" key for another
DAILY MODE (Daily Distance)
3 seconds to automatically to go to ID scan.
It measures the running
distance in a day.
KCAL MODE (Calories Mode)
Note:The measurement will
It displays the accumulated calories consumed from the beginning of the trip onwards.
automatically return to zero when
How to input gender, weight scale and weight.
Press "SET" key for 3 seconds to go to KCAL setting. Press "SET" key again to select Kg or Lb.
passing every 12:00 and 24:00
Press "MODE" key to go to weight setting, Input your weight by pressing "SET" key.
o'clock.
Press "MODE" key to go to gender setting, Press "SET" key to select Female or Male.
Press "MODE" key for 3 seconds back to KCAL MODE.
(Except E512, E517C)
2
The odo accumulated
S
from bike 2
M
M
S>3SEC
M
M
M
M
M. CAD (Maximum Cadence Mode)
(Option in E517C, E520C, E526AC)
Maximum cadence (pedals
revolution per minute)
from the beginning
onwards.
(Option in E523A, E526AC)
S>3SEC
(Option in E523A, E526AC)
S
M
S>3SEC
M
M
M
M
M
S>3SEC
M
M
M>3SEC