EasyPro EXP7500 Instrukcja instalacji i obsługi - Strona 2

Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Pompa wodna EasyPro EXP7500. EasyPro EXP7500 9 stron. Self-priming external pumps

EasyPro EXP7500 Instrukcja instalacji i obsługi

IMPORTANT SAFETY INSTRUCTIONS

Please read all instructions completely before installing or operating the pump.
Save this manual for future reference regarding installation, operation, maintenance and troubleshooting
of this pump. Please carefully read and follow all safety instructions and procedures listed on the pump
PRESSURE
HAZARD
Do not run your pump with
discharge ports closed or blocked.
Be sure to release system pressure
before working on the pump.
1.
This pump and motor unit should be installed by a qualified electrician or service person in accordance
with all applicable state and local codes and ordinances, and in accordance with the National Electrical
Code. Improper installation may create a mechanical or electrical hazard which could cause damage
to property and could result in serious injury or death.
2.
In order to avoid serious injury or death, always disconnect power to the motor before servicing
the pump and follow all instructions in this manual.
3.
Always use the schematic on the motor for all electrical connections.
4.
Never run the pump dry. The priming pot must be filled with water and lid secured before starting
the motor. Running dry will void the warranty and can result in permanent damage to the pump unit.
5.
To prevent incorrect motor rotation, install a ball or swing type check valve.
Do not use spring check valves.
6.
Maintain a minimum flow rate of at least two gallons per minute to avoid damage to the pump unit.
7.
Visually inspect the pump and motor a minimum of once per week. If any leakage between the motor
and pump housing is present, replace the mechanical seal . The seal faces wear similar to car tires
and must be replaced periodically. For critical applications, replace the mechanical seal yearly. If pump
is excessively noisy, shut it down and contact support.
8.
In freezing environments it is advisable to winterize your pump to prevent damage. Do not allow pump
or system plumbing to freeze, as freezing can cause damage that may lead to equipment failure or
possible injury and will void the warranty.
Scan the QR code at the bottom of page 3 or visit www.easypro.com/exp-series-pumps for pump winterization tips.
SELF-PRIMING EXTERNAL PUMPS
and in this manual.
ELECTRICAL
HAZARD
Ground pump before connecting
to power supply.
Risk of shock, burn or death if not
handled properly.

GENERAL WARNINGS

The All-In-One Pump
BURN
HAZARD
Operating motor can be very hot.
Do not touch motor while running.
Risk of Burn: Allow to cool 30
minutes after shutdown before
handling.
© 2023 EasyPro, Inc
Pg. 2