7. Electronic error codes
7.1. General
A common fault on grinders is that the motor is overloaded. There
are three levels of overloading.
OCF = Rapidly rising current
OHF = Rapidly rising current
OLF = Overload motor
All the error codes that may occur in the frequency converter in the
control cabinet are listed below.
Table 7-1:Electronic error codes
Error code
Cause
OCF
OCF = Rapidly rising current
Due to a high short-term load that is
2.5 times the nominal current over a
certain period. This usually occurs
if you run into something or if either
the grinding discs or something
else inside the machine locks up.
May also occur if the motor short
circuits.
OHF
OHF = Rapidly rising current
A less severe version of the same
fault above. Due to a high short-
term load that is 2 times the
nominal current over a certain
period. Usually occurs as a result
of high power consumption over a
prolonged period. May also occur at
high temperatures (+ 50° C).
InF / EEF
InF / EEF = Internal fault
Fault in the frequency converter.
SCF
SCF = Short circuit in the motor
Due to a short circuit in the motor or
the motor cable. May also be due to
an earth fault.
2.0
Electronic error codes
Action
Check mechanical inertia, spin the
grinding discs. Reset the converter
if the machine is sluggish. Remove
the plug for the motor and start the
converter to see if the fault remains.
See also the point below. Contact
HTC Service Centre if the fault
remains.
As the fault is related to the above
fault, the action indicated there
should be carried out. If the surface
being worked on is very tough, this
may cause this fault. If the fault is
temperature-related, the machine
must be left to cool down before
it can be started again. Another
solution is to reduce the speed of the
grinding discs to half speed, as the
machine will then use less power.
Contact HTC Service Centre.
Check the wiring and, if necessary,
the motor isolation. Test by
loosening the motor cable and
starting the frequency converter to
see if the error code appears. If this
occurs, the fault is in the frequency
converter, otherwise the cable or
motor is broken.
25