HTC 800 Classic Podręcznik - Strona 31
Przeglądaj online lub pobierz pdf Podręcznik dla Maszyna podłogowa HTC 800 Classic. HTC 800 Classic 36 stron.
HTC 800 Classic
7.2.1
Resetting the frequency converter
•
Press and hold the "RESET" button in for two seconds.
7.2.2
Checking the last error code
1. Press FUNC, D01 is shown in the display.
2. Press "arrow up", until D08 is shown in the display.
3. Press FUNC, the error code is shown in the display.
4. Press FUNC again, the current frequency is shown in the display.
5. Press FUNC once again, the motor voltage is shown in the display.
6. Press FUNC once again, the voltage of the DC bus is shown in the display.
•
Press "arrow up", until D09 is shown in the display, in order to see the previous
error codes.
7.3
Omron MX2
Error
Cause
code
E01
Excess current at constant
speed
E02
Excess current during
deceleration
E03
Excess current during
acceleration
E04
Excess current under other
conditions
E05
Overload
E08
Internal EEPROM error due to
overheating or interference
E09
Under-voltage
E10
Internal current supply error
E11
Internal processor fault
1.0
Action
The machine is running too fast or with too great a load.
Lower the speed, lower the load by changing the position of
the weights and check your tools. Check mechanical inertia,
spin the grinding discs.
See E01
See E01
See E01
See E01
Open the electrical cabinet and allow to cool. Check the filter
and the cooling fans in the cabinet. Let the frequency
converter cool down before restarting.
The connection cable is too long, poor connection or too
many consumers connected to the mains. Change socket, use
shorter cables and lower the speed.
Contact HTC Service Centre.
Reset the electronics using the Reset procedure.
Electronic error codes