BAP412
Figure 1
A
D
B
C
Figure 3
U.K. and IRELAND
PLEASE READ AND SAVE THESE
IMPORTANT INSTRUCTIONS.
With proper care and use, this Bionaire
air purifier will give you fresh, clean air
Figure 2
for many years.
NOTE: Before reading these instructions, please
view the corresponding illustrations.
E
DESCRIPTIONS (SEE FIG. 1-2)
A. Inlet Grill
B. Washable Foam Pre-Filter
F
C.HEPA/Carbon Filter
D. Filtered Air Outlet
E. Ionizer Light
F. Ionizer Control
G
G.Speed Control
SAFETY PRECAUTION
Carefully read and retain all instructions before
using the air purifier.
• To avoid fire or shock hazard, check that the
voltage on the product corresponds to your
electricity supply and plug directly into an
electrical outlet.
• To avoid fire hazard, never put the cord under
rugs, or near any heat source.
• Carefully discard any plastic wrapping that was
used for the packaging.
• Do not use the air purifier outside.
• Do not place the unit near any heat source or
in direct sunlight.
• Always unplug the air purifier before removing
Figure 4
the grill, changing the filters, cleaning the air
purifier or whenever it is not in use.
• Do not use in or around water or any other liquids.
Do not attempt to wash the unit under running
water.
• Use appliance only for intended household use
as described in this manual.
• Ensure that all air openings are not restricted
or covered in any way.
• Do not place anything on top of the unit.
• Never insert any object into any openings.
• Do not use the air purifier if any part is missing
or damaged in any way.
• Do not attempt to repair or adjust any mechanical
functions of this unit. If the unit becomes damaged
return to the place of purchase or phone the
helpline number on the back of this leaflet.
• If the supply cord or plug is damaged, it must
be replaced by the manufacturer or its service
agent or a similarly qualified person in order to
PRE-OPERATING INSTRUCTIONS
avoid hazard.
• The air purifier contains no user serviceable
1. After removing the unit from the box, remove
parts and should the product suffer damage or
the plastic covering from the unit.
breakdown it must be returned to the manufacturer
2. Select a firm level place where there are no
or its service agent.
obstructions to the air inlet (front grill) or filtered
• Should the air purifier stop working, first check
air outlet.
®
the fuse in the plug (UK only) or fuse/circuit breaker
3. Remove the inlet grill by pulling the grill towards
at the distribution board is operating, before
you.
contacting the manufacturer or service agent.
4. Remove both HEPA filters by gripping on both
sides and pulling forward.
HOW THE AIR PURIFIER WORKS
5. Remove protective plastic bag from each filter
Dirty, dust laden air is drawn through the back of
cartridge. The filter clip can only be attached to the
the air purifier and through the multi-stage filtration
hang tabs on the filter one way (see Figure 3). The
system.
filter clip should easily slide onto the filter hang
1. The carbon filter will help clear odours making
tabs. Do not use force whilst attaching the filter clip
the air cleaner and fresher.
to the filter. Align the clip on the HEPA filter with the
2. The HEPA filter entraps 99% of all smaller visible
rails on the inside of the unit. (see Figure 4)
and non-visible particles down to 2 microns in
NOTE: The pleated material and rubber gasket
size.
should be facing towards the unit when applied.
PRODUCT FEATURES
6. Replace the inlet grill by sliding back on to the
unit. Make sure that it snaps securely into position
Ioniser
(the grill only goes on one way).
Your Bionaire
®
Air Purifier has an independently
NOTE: Do not point outlet towards wall.
controlled ioniser, which when turned on, releases
OPERATING INSTRUCTIONS
negative ions into the outgoing filtered air. Ions
are tiny particles that carry either a positive or
1. Plug into a suitable 220 – 240V electrical outlet.
negative charge. These ions exist naturally all
2. Select the required operating Speed: Hi (
around us in the air, water and ground. Both positive
Medium (
and negative ions are colourless, odourless and
to the appropriate setting.
completely harmless.
3. To release negative ions into the filtered air,
Negative ions help the air purification process by
slide the Ioniser button (
attaching themselves to very small airborne particles
light will illuminate.
in the room. These particles take on a negative
4. The ioniser will not work unless the unit is running.
charge and may join with positively charged particles,
5. For optimum air filtration, it is recommended to
such as dust, pollen, smoke and pet dander to form
operate the air purifier continuously. Its rugged
larger particles that are then more readily captured
motor is designed to give many years of service.
by the filter system, or they may be attracted to
positively charged surfaces like walls or floors.
6. For continuous use, it is recommended to
operate the air purifier at the Medium (
You may also note, after extended use, that dust
setting. For quieter operation or use in a
may have collected around the grills or front panel.
bedroom, select the Low (
This is from the ionisation effect caused by the
high levels of air pollution are present, select
negative ions exiting from the air outlet.This dust
the Hi (
does not come from the air output, but is drawn
filtered air.
out of the uncleaned air going past the air outlet.
CLEANING AND MAINTENANCE
This is additional evidence of the air cleaning
effectiveness of negative ions. The dust can be
1. Turn the air purifier off and unplug it before cleaning.
easily removed with a clean, dampened cloth or
2. The outside of the air purifier can be cleaned
soft brush.
with a soft, clean dampened cloth.
NOTE: it is important to change the HEPA filter
3. The filtered air outlet can be cleaned of dust
at recommended intervals. Using the ioniser in
with a small, soft brush.
conjunction with dirty filters may result in dirty
4. If you wish to clean the inside of the air purifier,
particles exiting the air purifier and being attracted
please only use a dry, soft cloth to wipe it down.
to walls, carpets, furniture and other household
objects. These dirty particles may prove very difficult
FILTER REPLACEMENT
to remove.
IMPORTANT: IN ORDER TO RETAIN THE
EFFICIENCY OF YOUR AIR PURIFIER, THE
HEPA FILTER NEEDS TO BE CHANGED EVERY
2
6 MONTHS.
NOTE: Your air purifier has a filter condition sticker
that servers as a colour coded reference point.
1. Every few weeks check the condition of the
pre-filter.
2. Remove the inlet grill. If the foam pre-filter has
collected a noticeable amount of dust, remove
it from the inlet of the grill and wash it in warm
soapy water. Rinse and dry the pre-filter thoroughly
before replacing it in the inlet of the grill.
3. With the inlet grill removed, remove the HEPA
cartridge and dispose in the dustbin. DO NOT
try to wash and re-use the HEPA filter. Replace
with a new HEPA filter-BAPF30 removing the
protective plastic bag before inserting into the
air purifier.
4. Align the clips on the side of your HEPA filter with
the rails on the inside of the unit. Gently slide
the filter onto the rails.
5. The filter clip should easily slide onto the filter
hang tabs. Do not use force while attaching the
filter clip to the filter. Align the clip on the side of
your HEPA filter with the rails on the inside of
the unit.
NOTE: The pleated material and rubber gasket
should be facing towards the unit when applied.
6. Replace the inlet grill by sliding back on to the
),
unit. Make sure that it snaps securely into position
), Low (
) by sliding the switch
(the grill only goes on one way)
NOTE: Do not point outlet towards wall.
) to ON. The amber
REPLACEMENT FILTER
BAPF30 HEPA Filter (usage 1 pc)
Holmes Products Europe reserves the right to
change or modify any specifications without notice.

TROUBLESHOOTING

)
Problem
Solution
) setting. When
Unit will not operate. Check to make sure the unit
is plugged in.
) setting to quickly circulate clean
Check to make sure the unit
is on by turning the knob.
Make sure the filters are
properly installed and firmly
close the door.
Decreased airflow.
If the filters have not been
changed for 6 month or more,
change the HEPA filters.
Check to ensure nothing is
blocking the air inlet and
filtered air outlet.
Noise
Make sure filter bags are
removed if present.