LOCATION
The space for the location of your Newport heater must be large enough to provide the required clearances (see
installation diagrams - Pages 2 and 3).
finished with a light gauge metal, preferably stainless steel. Particular care must be taken to protect the surfaces
close to the edge of the top cooking surface and the chimney stack.
The location should also take into account the length and configuration of the flue stack.
Ideally your Newport should face the bow or the stern however, in most installations, the stove faces port or
starboard. Fuel gravity feeds from the oil-metering valve into the burner.
level of the burner fuel will not flow into the burner and the fire will go out.
installation or in a fore and aft installation in a boat which will list or heel for any length of time THE OIL
METERING VALVE MAY REQUIRE TO BE RE-LOCATED EXTERNALLY ON THE LEFT OR RIGHT SIDE
OF THE HEATER. If you have are in doubt regarding the need for a valve re-location please ask your dealer
or call dickinson on our 800 number.
MOUNTING AND SECURING
1)
Unscrew the acorn nuts on the front bottom panel and remove the front of the stove
2)
Secure the tie-down bar (supplied) to the floor 2 ins from the back of the prepared area.
The raised ends of the bar must be up to allow the side flange of your stove to slide underneath.
3)
The stove must be leveled and secured at the front through the bolt holes at the base of the side panels
4)
The finishing tray (supplied) must be installed under the stove
FLUE STACK
The length and straightness of the flue stack are important to the efficient operation of the stove
Diameter
Recommended Length -
Notes -
Stack must be correct diameter
Elbows in excess of 45 degrees not recommended
Elbows greater than 45 degrees MUST not be used.
A Barometric Damper is recommended for all installations but must be installed in flue
stacks longer than the recommended lengths
The ROUND pipe is squeezed to fit the OVAL flue collar on the stove
THROUGH DECK FITTING
Gasket or Sealing
Compound
Internal Dress Ring
INSTALLATION
It must be lined with high density, heat retardant insulation and
-
5 ins (12.70cm)
6 ft ( 1.829m)
Should this valve drop below the
In a fore and aft SAILBOAT
Through Deck-Fitting
Teak Leveling Block
4
Deck