Dickinson Newport - P9000 Instrukcja instalacji i obsługi - Strona 3

Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Kominek wewnętrzny Dickinson Newport - P9000. Dickinson Newport - P9000 12 stron. Propane fireplace/heater

Model
Type
Ignition
Fuel
Fuel
Consumption
Fuel Line
Heat Rating - Fan Off -
Heat Rating - Fan On
Heater Dimensions
Weight
Blower Fan Power Source
Power Consumption
S/S Flue Pipe - Flexible -
S/S Flue Pipe - Flexible -
Double Flue Outlet
www.ahoycaptain.com

SPECIFICATIONS

-
NEWPORT PROPANE FIREPLACE/HEATER
-
DIRECT VENT
-
MANUAL
-
LPG (Propane/Butane)
Low Pressure – 11 ins water column
-
1lb bottle
20lb bottle
-
3/8 ins copper or approved hose -
3/8 ins flare fitting
Low
3100BTU/h - 727kcal/h ( 844w/h)
High
-
Low
6428BTU/h - 1507kcal/h (1749w/h)
High
-
Height
Width
Depth
Mounted Depth
-
15 lbs (6.82 kg)
-
12VDC
-
Power jack for 120VAC to 12VDC installed.
(500ma 2.1mm Centre Positive)
( Dickinson Part No. 19-010)
-
.17amp
Inner nominal - 1.5 ins (37.5mm) diameter.
Outer nominal - 2.5 ins (62.5mm) diameter
Minimum Operating Length - 24ins (60cm)
Maximum Operating Length - 60 ins (1.5m)
-
Height above deck
Deck Flange diameter - 6 ins (15cm)
Deck Mount hole size
- Low
7 hrs : High
- Low 140 hrs : High 100 hrs
4300BTU/h - 1008kcal/h (1170w/h)
9000BTU/h - 2110kcal/h (2449w/h)
- 14 ins (35cm)
- 8.5 ins (21.25cm)
- 5.5 ins (13.75cm)
- 6.5 ins (16.25cm)
5 hrs
- 4.5 ins (11.25cm)
- Min 3 ins (7.5cm)
3