Dickson TH8P5 Podręcznik użytkownika

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Przyrządy pomiarowe Dickson TH8P5. Dickson TH8P5 9 stron. Temperature & humidity chart recorder, 8” (203mm)
Również dla Dickson TH8P5: Podręcznik (8 strony)

Dickson TH8P5 Podręcznik użytkownika
DICK
DICKSON
DICK
DICK
SON
SON
SON
GETTING STARTED
GETTING STARTED
GETTING STARTED
GETTING STARTED
7-day chart rotation
o
+32 to 120
F (TH8P0/2)
o
-20 to +120
F (TH8P3/5)
QUICK START
QUICK START
QUICK START
QUICK START
1. 1. 1. 1. Remove the protective pen caps.
2. 2. 2. 2. Check to make sure the Replaceable Sensor is connected firmly to the recorder. If using
model TH8P3/5 make sure the extension cord is connected firmly to the recorder and
that the Replaceable Sensor is plugged in firmly to the extension cable.
3. 3. 3. 3. Insert batteries and plug in AC adapter (See Figure 3). TH8P0:4 AA batteries required;
TH8P2/3/5: 4 AA batteries backup power only (See Power section for backup life). Unit
will power on.
4. 4. 4. 4. The instrument will move pens to the appropriate readings.
5. 5. 5. 5. Install the chart that matches the Dip Switch settings (See Dip Switch Setup).
Press the PEN HOME
PEN HOME key to move the pens to the outside of the chart. The pen is
PEN HOME
PEN HOME
automatically raised off the chart.
Remove the old chart, place the new chart on the Chart Hub being certain that the edge
of the chart slides under the Chart Guide Clips located at the outside of the chart.
6. 6. 6. 6. Set the appropriate time. There are two ways to adjust the chart and set the appropriate
time:
a.
Set the chart time manually by inserting a coin into the groove in the chart hub
and turning clockwise until the correct hour (and day if applicable) on the chart is
referenced to the timing arrow (just to the right of the pen tip on the dial). Press
Pen Home to move the pens back onto the chart.
Pen Home
Pen Home
Pen Home
The following feature should be used for fine adjustments only.
b. To adjust the chart time, press and hold Adjust
located on the back of the unit next to the dip switch (see Figure 3).
The green LED will blink rapidly for about five seconds, then the LED will remain
solid green. While in this state the Adjust
backward (counter clockwise) and the Adjust
forward (clockwise).
Rotate the chart until the correct hour (and day if applicable) on the chart is
referenced to the timing arrow. Once you have set your chart, press the Pen
Home button to exit Chart Adjust Mode. The unit will take one minute to exit the
Home
Home
Home
Chart Adjust Mode once Pen Home
back onto the chart.
c.
Place the TH8recorder on a flat vibration-free surface. Be sure it is in a vertical
position and level. For best performance and longevity, the location should be a
clean environment, free from dust and corrosive fumes. Do not exceed
temperature specifications. Wall Mount: Keyhole slots are provided on the
TH8recorder for wall mounting.
Dickson TH8P Manual V14 052418
Temperature & Humidity Recorder
Temperature & Humidity Recorder
Temperature & Humidity Recorder
Temperature & Humidity Recorder
Adjust- - - - Up
Up and Adjust
Adjust
Adjust
Up
Up
Adjust
Adjust
Adjust- - - - Up
Up button will move the chart
Up
Up
Adjust
Adjust- - - - Down
Adjust
Down button will move the chart
Down
Down
Pen Home
Pen Home is pressed. Press Pen Home
Pen Home
1
TH8P0/2/3/5
TH8P0/2/3/5
TH8P0/2/3/5
TH8P0/2/3/5
Adjust- - - - Down
Down buttons
Adjust
Adjust
Down
Down
Pen
Pen
Pen
Pen Home to move the pens
Pen Home
Pen Home