GENERAL INFORMATION

Generally speaking, it is necessary to comply with the current building rules and regulations for
fireboxes in the country of use, as well as with all local, national and European standards.
Important before use:
-
Make sure your furnace operates properly; it is important to read this manual
carefully and to strictly follow the instructions therein.
-
Use only the recommended types of fuel - wood logs and brown coal briquettes.
-
The required discharge pressure for normal workload should be approximately 12
Pa. For the discharge pressure over 15 Pa, you should use the built-in damper valve
in the outlet pipe.
-
In the room where the furnace is installed, it is necessary to make sure there is
sufficient supply of fresh air into the firebox. If the windows and doors are sealed, or
if other appliances, such as steam extractors, dryers, fans, and so on, drag the air
out of the room where the furnace is located, then the combustion air (fresh air)
needs to be brought in from the outside, as necessary. In this regard, it is necessary
to consult with a competent chimney organization before the furnace is set up.
-
You must not keep any flammable materials in the ash tray. The filling height must
not exceed the height of the side walls of the ash tray.
-
Furnace and ash area door must be kept closed (except for ignition, insertion of fuel
and ash cleaning), to prevent the release of hot air.
-
The furnace must not be changed, except in case of our offered, tested and original
parts and accessories, and if the changes are made by our factory service center.
-
In case of fire in the chimney, the furnace door should be kept closed, and so should
the air regulator! Never attempt to extinguish a fire in the chimney by pouring water
in it. The water vapour which is formed in the chimney can cause explosions. If
necessary, use the emergency phone number to call the fire department!
-
If interference occurs, close all air regulators and do not insert new fuel into the
furnace until the cause of the problem is eliminated!