inseconds. It startsat5 andcounts
down to0.
3.CoolDown -Aftercranking, thechar-
gerenters a mandatory 3-minute ( 180
second) cooldown state. D uring this
period, nosettings can bechanged. The
buttons areignored. The digital display
indicates the remaining cool down time
inseconds. Itstarts at180 and counts
down t o0.The 125A S TART L ED blinks
onceeverysecond. During thecool
down period, nocurrent isdelivered to
thebattery. After3 minutes, the125A
START L ED willstop blinking a ndwilt
lightcontinuously,
indicating thatan-
other c rank cycle canbestarted. The
digital display will c hange from display-
ingthecountdown back todisplaying
thebattery v oltage. TheCHARGING
LED will b elitagain.
ENGINE STARTING NOTES:
• If the battery
is disconnected
during
the cool down period, the charger wilt
reset.
OVERVIEW
Using this battery charger is very simple.
First, connect the battery and AC power
following
the precautions
listed under
"OPERATING
INSTRUCTIONS".
Then
select the appropriate CHARGE TYPE and
CHARGE RATE for your battery. The char-
ger will then do everything automatically.
This section explains a few details.
CHARGING:
If the charger
does
not
detect a properly connected
battery, the
CHECK (red) LED wilt light continuously
until such a battery is detected. Charging
will not begin while the CHECK LED is on.
When charging begins, the CHARGING
LED will be lit.
AUTOMATIC
SHUT OFF: When the 2A,
15A or 40A charge rate is selected, the
charger
is set to perform
an automatic
charge.
When an automatic
charge
is
performed,
the charger
stops charging
automatically after the battery is charged.
ABORTED
CHARGE:
If charging can't
be completed normally, charging will be
aborted. When charging is aborted, the
charger's output is shut off and the red
CHECK LED and digital display blink on
and off (at opposite times). In that state, the
charger ignores all buttons. To reset from
after an aborted charge, either disconnect
the battery or unplug the charger.
DESULFATION
MODE:
If a battery
is
left discharged for an extended period, it
could become sulfated and not accept a
normal charge. If the charger detects a
sulfated battery, the charger will switch to
a special mode of operation designed for
such batteries. Activation
of the special
desulfation mode is indicated by blinking
the CHARGING
LED. If successful,
nor-
mal charging will resume after the battery
is desulfated.
The CHARGING
LED will
then stop blinking and light continuously.
Desulfation could take up to 10 hours. If
desulfation fails, charging will be aborted
and the CHECK (red) LED will blink.
COMPLETION
OF CHARGING:
Charge
completion is indicated by the CHARGED
(green) LED; when tit, the charger has
stopped
charging
and switched
to the
Maintain Mode of operation,
if the DEEP
CYCLE charge type was selected.
For
other charge types, the CHARGED
LED
comes on when the battery is charged
enough for normal use.
MAINTAIN MODE: When the CHARGED
(green) LED is tit, the charger has started
Maintain Mode. This mode of operation is
also known as Float-Mode Monitoring.
In
this mode, the charger keeps the battery
fully charged by delivering a small current,
when necessary. The voltage is maintained
at a level determined
by the CHARGE
TYPE selected. NOTE: For charge types
other than DEEP CYCLE, the CHARGED
LED might be lit before Maintain Mode is
started.
GENERAL
CHARGING
NOTES:
The
charger is designed to control its cooling
fan for efficient operation. Consequently, it
is normal for the fan to start and stop when
maintaining a fully charged battery. The fan
does not run in Tester Mode.