DieHard 200.71231 Instrukcja obsługi - Strona 15
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Ładowarka DieHard 200.71231. DieHard 200.71231 16 stron. Battery charger 50/15/2 amp manual engine starter with battery tester 225/125 amp
Również dla DieHard 200.71231: Instrukcja obsługi (14 strony)

Troubleshooting
Performance problems often result from little things that you can fix yourself. Please read through this table for a
possible solution if a problem occurs.
PROBLEM
No reading on the
ammeter.
No reading on
ammeter, charger fan
not working.
No reading on volt-
meter.
Voltmeter pointer
always to righthand
side of meter.
Circuit breaker in
charger cycles on
and off with a
clicking sound.
Short start cycle
when cranking
engine.
Ammeter reads less
than selected charge
rate when charging
a discharged battery.
Charger makes a loud
buzz or hum.
POSSIBLE CAUSE
Clamps are not making a
good connection.
2 amp charge rate is
being used.
AC cord and/or extension
cord is loose.
Poor electrical connection.
Battery severely
discharged,
Test switch may be in the
wrong switch position.
Battery severely
discharged.
Test meter may be in the
wrong switch position.
Shorted battery clamps.
Shorted battery.
Charger leads reversed.
Volt/Amp Selector Switch
set to the START position.
Drawing more than 225
amps for a period equal to
or less than 5 seconds.
Failure to wait for 4
minutes (240 seconds)
between cranks.
Extension cord too long
or wire gauge is too small.
Weak cell or sulfated
plate in battery.
The battery is only
partially discharged.
Transformer laminations
vibrate (buzz).
Shorted diode (hum).
SOLUTIONIREASONS
Check for poor connection at battery. Make sure
clamps and posts are clean. Battery may not want to
accept a charge due toexcessive run down state.
Ammeter may show no activity at the 2 amp setting.
Check AC outlet and extension cords for loose fitting
plug.
Check for open fuse or circuit breaker supplying AC outlet.
Continue to charge battery for another two hours. If
problem continues, call Sears Service at 1-800-SEARS-64.
Check if test switch is in proper 6 or 12 volt position.
Continue to charge battery for another two hours. If
problem continues, call Sears Service at 1-800-SEARS-64.
Check if test switch is in proper 6 or 12 volt position.
Circuit breaker cycles when current draw is too high.
Separate the clamps. Check for worn cables and replace
if needed.
Have a Sears Service Center test the battery.
Correct connections.
Correct Volt/Amp Selector setting.
Crank time varies with the amount of current drawn. If
cranking draws more than 225 amps, crank time may be
less than 5 seconds.
Wait 4 minutes before next crank.
Use shorter or heavier gauge extension cord.
Sulfated battery will eventually take a normal charge after
a period of time. If the battery will not take a charge, have
a Sears Service Center test the battery.
Continue to charge battery.
Continue charging. Buzz is not abnormal.
Have charger tested by a Sears technician.
If the above solutions do not ellmlnote the problem...
call toll-fl_e from anywhere In the U.S.A.
1-e00-SEARS-64
(1-e00- -TrS4)
7 AM to 4:30 PM CT Monday through
Fdday
14