Charge Time Needed if Amp-Hours is Known
•
Find the Charge Factor for your battery in the table on page 11.
•
Multiply by the Amp-Hour rating of the battery.
•
Divide by the Charger Setting (either 2 Amp or 12 Amp).
•
Multiply by 1.25 to get the approximate Hours Needed to bring the battery to full
charge.
Example: 15 Amp-Hour (AH) Battery, 50% State-of-Charge,
[(AH x Charge Factor) ÷ Charger Setting] x 1.25 = Hours Needed
(15 x 0.5 ÷ 2) x 1.25 = 4.7 Hours
Charge Time Needed if Reserve Capacity is Known
•
Find the Charge Factor for your battery in the table on page 11.
•
Multiply by the Reserve Capacity rating of the battery.
•
Divide by the Charger Setting (either 2 Amp or 12 Amp).
Multiply by 0.73 to get the approximate Hours Needed to bring the battery to
•
full charge.
Example: 95-Minute Reserve Capacity (RC) Battery, 25%
[(RC x Charge Factor) ÷ Charger Setting] x 0.73 = Hours Needed
[(95 x 0.75) ÷ 12] x 0.73 = 4.3 Hours