Insertion of silica gel
Before sealing the Case, insert the accessory silica gel bag for
prevention of fogging between the bottom of the camera and the
Case. Insert the bag with the glued longer side to the inside.
Pay attention to the orientation.
CAUTION
: • Insert the silica gel all the way at the specified location
and with the specified orientation. When the orientation is
not correct, the silica gel bag will be caught when the
Case is sealed and water leakage will be caused.
• When it is tried to seal the Case with the bag inserted
only part of the way, the silica gel bag will be caught by
the O-ring and water leakage will be caused.
• Once silica gel has been used, the moisture absorption
performance will be impaired. Always exchange the
silica gel when the Case is opened and closed.
Check the loading status.
Always perform the following final checks before sealing the Case.
Has the silica gel been inserted all the way at the specified
position?
Has the O-ring at the Case opening part been installed properly?
Are the O-ring and the O-ring contact surface on the front lid free of
dirt and other foreign matter?