ASSEMBLY
3-1 Assembly Diagram
# For the assembly and adjustments of the unit, have Olympus perform them.
# After re-assembling the module, re-adjustments are required. Consult Olympus in such a case.
}For the connection using an RS-232C cable (to be prepared by the user) and computer, refer to the instruction manuals
for the BX-UCB control box and U-HSTR2 hand switch.
CAUTION
The BX-RLAA motorized vertical illuminator will not work properly if the connector of the U-UCD8A
motorized universal condenser is connected to the BX-UCB control box. Be sure to detach the
connector before using the illuminator.
}In consideration of the observation of metallurgical specimens, it is recommended to use a dedicated metallurgical stage
or replace the specimen holder with a stage plate to improve the ease of operation.
If only the stage plate is replaced, the back surface of the stage plate may be worn after long period of use because the
upper surface of the biological stage is coated with ceramic.
Brightfield/darkfield
objectives
(See page 2 for
details on the
applicable
Brightfield objectives
objectives.)
(See page 2 for details on
the applicable objectives.)
Rotary wafer holder
BH2-WHR43
Wafer holder
U-WHP2
Stage
clamping
knob
4 x 4 inch stage
U-SIC4R2/SIC4L2
* Warp prevention pins (2 for each) are attached on the bottom sides of the U-MSSP/MSSP4 stage plate and the U-
MSSPG glass plate when the system is shipped from the factory. Remove the pins before use.
** Attach the MX-AFDIC so that the model nameplate faces straight the rear.
CAUTION
When a brightfield objected is mounted on the revolving nosepiece by means of the BD-M-AD objective
adapter. the AF centering error may occur. In this case, the AF performance of the system cannot be
guaranteed.
Stage plate
U-MSSP4*
Glass plate
U-MSSPG*
Stage plate
U-MSSP*
Stage
U-SVRM/
Stage
SVLM
clamping
screw
Hand switch
U-HSTR2
Observation tube
U-BI30-2 U-SWTR-3
U-TR30-2 U-SWETR
U-ETR-4
U-SWET TR-5
U-TLU
MX-SWETTR
Analyzer slot unit**
MX-AFDIC
Active AF unit
U-AFA2M-VIS/U-AFA2M-DUV
Motorized vertical
illuminator
BX-RLAA
BXFMA-F
For brightfield objectives
For brightfield/darkfield
objectives
Motorized microscope frame
BX61TRF
Control box
BX-UCB
U-AFA2M
Analyzer
U-AN
AF cable
U-AFA2M-
CBL2M/3M
Motorized revolving
nosepiece
AF control board
U-AFA2M-CB