AccuLine 40-6680 Instrukcja serwisowa - Strona 14

Przeglądaj online lub pobierz pdf Instrukcja serwisowa dla Akcesoria AccuLine 40-6680. AccuLine 40-6680 16 stron. 5 beam laser pointer
Również dla AccuLine 40-6680: Instrukcja obsługi (13 strony)

AccuLine 40-6680 Instrukcja serwisowa
2.
When the up and down laser points
are beyond tolerance as shown in
the figure to the right, you can
adjust the pendulum adjusting
screw to calibrate (see below).
When the instrument is in the
state 5, you need to twist the
pendulum adjusting screw
clockwise using an inner
hexagon spanner.
If in the state 6, you need to
twist the pendulum adjusting
screw count-clockwise.
Prepared By: Tim Wojo
Up Laser Point
Circle with a diameter of
Reference Point
State 5
Circle with a diameter of
Reference Point
Up Laser Point
State 6
Revision - Date: 0 – 20080430
40-6680 Service Manual
Down Laser Point
Circle with a diameter of
Reference Point
Circle with a diameter of
Reference Point
Down Laser Point
Page 14 of 16