Setup/Adjustments
Setting the table clearance
The gap between the table and the disc should be set to
a maximum of 1.6mm to clear the debris and to ensure
sufficient support for the timber.
The table should be positioned so that sanding only occurs
from downward movement of the disc face. Small pieces of
timber should not be disc sanded. A responsible person
should check the setting of the machine before use.
Step 1 To set the table clearance, first remove the guard by
undoing the two Phillips screw (a), place screws and guard
safely aside (see fig 01).
Fig 01
Fig 02
c
Step 2 Locate the supplied spanner (C) loosen the six nuts
beneath the table brackets, (see fig 02) place a rule up
against the sanding disc and adjust the table until there is a
1.6mm clearance between the table and the disc, (see fig 03).
Step 3 Replace the disc guard as described above.
Step 4 Place the 90˚ square against the disc and mitre fence,
(see fig 04) to check the table is square then tighten the six
nuts beneath the table.
Place a rule up against the sanding disc and adjust the table
until there is a clearance of 1.6mm.
a
Step 5 Place the square upright against the sanding disc,
loosen the two clamping handles (b) on either side of the
table and adjust the tables angle, until it's perpendicular to
the sanding disc (see fig 05). Tighten the clamping handles.
8
90˚Square
NOTE: MAKE SURE THE MITRE
FENCE IS SET TO ZERO ON THE
SCALE!
90˚Square
Fig 03
Fig 04
Fig 05
b