Input Stages and switching
The inputs are split into two groups with the Wolfson SPDIF receiver at location IC201 dealing
with Optical and Coaxial selection whilst the MUX at locations IC202A IC202B and IC205A
switch between SPDIF (opt or coax) and USB or KLEER under control from main micro.
SPDIF input
The Wolfson WM8805 SPDIF receiver supplies data in a format of Data , LRCLK, BCLK and MLCK,
the output of IC201 runs directly to the DAC via the MUX at location IC202A with exception of
the MCLK this take a path thru IC203 as part of the MCLK MUX between USB / KLEER and SPDIF
MCLK's.
USB input
The USB data arrives at CON100 before traveling to the USB streaming control chip at location
IC103 via the ESD protection Chip at location IC101 the chip is loaded with the DCS
asynchronous/isochronous input system from IC100 at boot up.
IC103 has it own MCLK source at location IC204 another WM8805 this time used as an adaptive
clock source the output is buffered by IC203C
The Data , LRCLK, BCLK are switched to the DAC via IC202B with the MCLK coming via IC203.
DAC and Audio Stages
circuit page 4
The Wolfson 8741 DAC can be found at location IC301 and takes its supplies from 3V3D and
5VDAC, data enters the chip on pins 1 – 5 and should be seen as below.
Pin loc
Signal type
Pin 1
LRCK
Pin 2
SDATA
Pin 3
BCK
Pin 5
MCLK
Analogue audio leaves the DAC as balanced pairs on pins 16 / 17 (left) and 12 / 13 (right) audio
then travels thru and filter network enters the Op‐amp at location IC300 a/b (L/R) and then
onto IC302 a/b (L/R) output muting is twofold with both DAC mute (transistor mute) and full
mute (relay) the DAC mute is provided by transistors TR302 and TR305 switching the audio
down to 0v this under the control of the DAC MUTE line from IC107, the relay mute is provided
by RLY300 and triggered from 2 lines one being the power detect sourced from D400 at power
In – under low power the relay will close at 5.3v D.C and is flipped by IC105 in combination with
IC104 the output of IC104 is low to mute the relay is switched by TR300.
Circuit pages 2 and 3