Axxent AX-4240TS-D Instrukcja obsługi - Strona 3

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Wzmacniacz Axxent AX-4240TS-D. Axxent AX-4240TS-D 4 stron. Professional 4-channel power amplifiers

1
2
REAR OF THE AMPLIFIER
1: On the far left you can see the large, sturdy mains
switch at the top. This is a rocker switch - in the upper
position on and the lower position off.
2: Below the mains switch is the mains input socket
according to the international IEC standard. Delibe-
rately, no permanently connected mains cable was
used here, so that the mains cable can be easily re
moved in case of a possible malfunction of the ampli-
fier. The mains cable is included with the amplifier.
The mains input socket also includes a fuse holder.
If the amplifier malfunctions, i.e. if you have switched
on the amplifier and the green „Power" LEDs do not
light up, the mains fuse may be defective. Please call
the technician and, if possible, do not replace it your-
self. Just in case: The mains fuse is 6.3 A (8 A for the
AX4240TS-D), slow-blow and has the dimensions
5x20 mm.
3: Digital Dante/AES67 input: To the right of the switch
and the mains input socket you will see an RJ45
socket. This is the input socket for a digital Dante/
AES67 signal. This digital input is fully compatible with
the usual Dante audio standard. In case of a digital
malfunction, there is a recessed reset button above the
RJ45 socket. This resets the set digital parameters
to the default settings. To the right of the RJ45 socket
are the digital/analogue selector switches. Here you
can select for each of the four amplifier channels
whether you want to use the digital or the analogue
input. Below the selector switch you will see a push-
button switch for selecting the digital input level. The
default setting is 0 dBu. In the depressed position
-9 dBu (see page 4)
axxent e.K. · Technologiezentrum Herzbachtal · Zum Wartturm 15 · 63571 Gelnhausen
fon: +49-6051-9165584 · fax: 9165585 · [email protected] · www.axxent.de
®
Operator's Manual AX-4120TS-D/AX-4240TS-D
3
4
(AX-4120TS-D AND AX-4240TS-D IDENTICAL)
Professional 4-channel power amplifiers
6
5
4: Analogue input sockets of the amplifier: The analogue
input sockets of the amplifier are designed as 3-pole
XLR sockets. These can be found on the lower side,
Input 4, Input 3, Input 2, Input 1. These inputs are
electronically balanced and have an input impedance
of 20 kOhm. Any standard microphone cable, desi-
gned according to international standards, can easily
be used here for connection to mixing consoles or
audio distribution units.
5: Between the connection Input 4, Input 3, and Input 2,
Input 1, there is a recessed pressure switch each.
These serve to activate the bridge mode of the respec-
tive input pair if required.
6: Output sockets of the amplifier: You see two 10-
pole, green terminal blocks. These are assigned with
the constant voltage outputs 70 and100 V as well as
with the low-impedance connections. In European
countries, 100 V operation is common. For constant
voltage operation itself, axxent has a manual „Basics
of 100 V loudspeaker systems". The connections are
designed as screw-terminal connections. As the screw
terminals are quite tight for safety, please use a small
tool (screwdriver or similar) to pull them out. Then you
can simply attach your stripped connection cables to
the terminals with a small slotted screwdriver.
7: Fan operation: The AX-4120TS-D/4240TS-D amplifiers
use a two-stage fan for rear-to-front airflow. The speed
of the fan is controlled by the temperature of the
internal transistor heat sinks. During high-performance
operation, the fan switches to level 2.
6
7
4
5
3