Method of serial data input to the PLL
After the RF channel table plan is decided, the data needs to be allocated to the ROM table and read from
there or calculated with the software.
Together with this setting data, operation bits that decide operation of the PLL must be sent to the PLL.
The operation bits for setting the PLL are as follows. These values are placed at the head of the reference
counter value and are sent to the PLL.
1.
CS: Charge pump current select bit
CS = 0
2.
LDS: LD/fout output setting bit
LDS = 0
3.
FC: Phase control bit for the phase comparator
FC = 1
2nd data
1st data
DATA
CLK
LE
STD-302
terminal name
The PLL IC, which operates as shown in the block diagram in the manual, shifts the data to the 19-bit shift
register and then transfers it to the respective latch (counter, register) by judging the CNT control bit value
input at the end.
1. CLK [Clock]: Data is shifted into the shift register on the rising edge of this clock.
2. LE [Load Enable]: Data in the 19-bit shift register is transferred to respective latches on the rising edge of
the clock. The data is transferred to a latch according to the control bit CNT value.
3. Data [Serial Data]: You can perform either reference counter setup or programmable counter setup first.
OG_STD-302N-R-419M_v10e
+/-1.5 mA select
LD select
N11
N10
N9
CS
LDS
FC
MSB
t1
t2
t0
#: t0,t5 >= 100 ns
#: Keep the LE terminal at a low level, w hen w rite the data to the shift resister.
VCO is optimized to +/-1.5 mA
Hardware is set to LD output
Hardware operates at this phase
Figure 2
1st Data
N8
N7
N6
SW
R14
R13
t3
t1,t2,t6 >= 20 ns
t3,t4 >= 30 ns
12
OPERATION GUIDE
A1
CNT=0
R1
CNT=1
Inv alid Data
LSB
t6
t4
t5
2nd Data
Circuit Design, Inc.