Arch PS 5000 Instrukcja obsługi - Strona 7

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Systemy filtracji wody Arch PS 5000. Arch PS 5000 16 stron.

Pulsar® 3 Chlorinator Inspection & Maintenance
Calcium Hypochlorite by the nature of its manufacture, contains a small amount of calcium carbonate. Proper
water balance will minimize the buildup of calcium carbonate solids in the Pulsar® 3 Chlorinator, however,
periodic cleaning of chlorinator components is normal and recommended. Th e following is a list of the parts to be
cleaned and the proper procedures to do so.
Suggested
Inspection
Frequency
As Needed
As Needed
Cleaning PULSAR® 3 Chlorinator with PULSAR® Plus Acid Cleaner 50
Inspection: Th e solids build-up and cleaning frequency required for the unit will depend on the amount of
Briquettes used and the pool water chemistry. Described below is the easiest way to remove solids and minor scale
buildup using the PULSAR® Plus Acid Cleaner 50.
WARNING
Do NOT use Muriatic Acid to perform the following procedures.
Chlorine gas may evolve causing serious injury or possible death.
Maintenance Procedure Steps:
1. Close the inlet and outlet shutoff valves to the chlorinator.
2. Lift the Briquette Tank off of the Spray Manifold Section and Discharge Tank and pour the contents into a clean
dry bucket. Be sure to remove all pieces of briquettes or tablets. If necessary, rinse any heavy solids buildup from
the tank before proceeding.
3. Remove briquette grid and place in black tub (provided with system). Fill with 1 gallon of water. Slowly pour ½
quart PULSAR® Plus Acid Cleaner 50 into tub and ½ quart PULSAR® Plus Acid Cleaner 50 into discharge tank.
Frequent agitation may be required to dissolve solids and scale. Allow acid to dissolve solids and scale, evident
by the foaming action. After 5 to 10 minutes, check for presence of scale on grid. If necessary, add additional
PULSAR® Plus Acid Cleaner 50 to dissolve any remaining scale or scrape with putty knife.
4. Pour the solution from tub into the discharge tank. Dispose of scale with backwash from fi lter.
5. Place the Briquette grid back into bottom of hopper.
Rinse the Briquette grid thoroughly with water and
open the inlet-shutoff valve to allow the spray to
rinse the grid from the bottom. Th e solution from the
Discharge tank will clean the discharge valve, tubing
and venturi when system is restarted.
6. Pour Pulsar® Plus Briquettes from bucket back into
Briquette Tank. Resume operation.
7. Open inlet and outlet shut off valves to the chlorinator.
NOTE: To increase the period between Grid cleanings,
allow Briquette Tank to completely empty once a week.
Table of Contents
Section
Section A
Use of Pulsar Plus Acid Cleaner 50 to remove solids
and scale from the Pulsar 3 Chlorinator
Section B
Troubleshooting Guide
SECTION A
– 4 –
Contents