Architectural Area Lighting PROS Providence Small Instrukcja instalacji - Strona 15

Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Oświetlenie zewnętrzne Architectural Area Lighting PROS Providence Small. Architectural Area Lighting PROS Providence Small 15 stron. Led upgrade kit

INSTALLATION INSTRUCTIONS
WARNING: THIS PRODUCT CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER
REPRODUCTIVE HARM. THOROUGHLY WASH HANDS AFTER INSTALLING, HANDLING, CLEANING OR OTHERWISE TOUCHING THIS PRODUCT.
O
1 1/2"
WIREWAY
3.5
13.94
10.00
O
(2)
CLEARANCE
5.0
MOUNTING PLATE
(ORIENTATION)
FRONT OF
FIXTURE
(2)CAPTIVE
SCREWS
DOME DETAIL
INSTALLATI O N STEPS:
1.
TURN OFF POWER.
2.
PLUG IN CONNECTORS FROM ARM TO FIXTURE.
3.
PULL LATCH AND LOWER FIXTURE TO ACCESS BALLAST;
ASSEMBLE FIXTURE TO ARM WITH (2) CAPTIVE SCREWS
(AS SHOWN), CLOSE LAMP COMPARTMENT.
4.
MAKE WIRE CONNECTIONS FROM INCOMING WIRE
LEADS TO ARM LEADS, AS SHOWN. (WHITE TO
COMMON, BLACK TO HOT AND GREEN TO GROUND).
NOTE: ASSEMBLY MUST BE GROUNDED TO THE
INCOMING EQUIPMENT GROUND SUPPLY.
5.
PLACE WIRING IN J-BOX AND MOUNT FIXTURE TO
MOUNTING SURFACE. (NOT FOR JUNCTION BOX
MOUNTING, HARDWARE BY OTHERS).
6.
SILICONE AROUND MOUNTING PLATE AND MOUNTING
SURFACE, AS SHOWN.
7.
INSTALLATION COMPLETE.
14249 Artesia Blvd. P.O. Box 1869
(714)994-2700 fax(714)994-0522
MOUNTING HARDWARE
(BY OTHERS)
ARM
CONNECTORS
(2)CAPTIVE SCREWS
7/16"
DOME
FIXTURE
La Mirada, CA 90638-1869
WIRE CONNECTIONS
(BY OTHERS)
CONNECTORS
BALLAST
1
TABS
FITTER CAP
LAMP (REFERENCE)
(BY OTHERS)
1.
2.
3.
4.
5.
6.
1.
2.
3. LIFT FITTER CAP FROM FITTER.
4.
5.
1
6.
8-32 X 1/4"
PHMS S/S
(2) P/N A84031
MOUNTING PLATE
LATCH
CLOSED
FITTER CAP DETAIL
BALLAST SERVICING:
TURN POWER OFF.
PULL LATCH AND LOWER FIXTURE TO ACCESS BALLAST.
UNPLUG ALL CONNECTORS AND REMOVE (2) SCREWS
TO RELEASE BALLAST.
SERVICE BALLAST.
PLUG IN ALL CONNECTORS, RE-INSTALL BALLAST
AND SECURE WITH (2) SCREWS. CLOSE FIXTURE AND
LATCH SECURELY.
BALLAST SERVICING COMPLETE.
LAMP SERVICING:
TURN POWER OFF.
ROTATE FITTER CAP COUNTER CLOCKWISE, UNTIL
FREE FROM FIXTURE. (SEE FITTER CAP DETAIL)
INSTALL LAMP (BY OTHERS).
CAREFULLY PLACE FITTER CAP INTO FITTER, ROTATE
FITTER CAP CLOCKWISE UNTIL TABS SNAP SECURELY
INTO FITTER.
LAMP SERVICING COMPLETE.
DATE
APPRVD
DATE
CATALOG NUMBER
PROS IND
TRA59D
INCOMING
WIRE LEADS
JUNCTION BOX
(BY OTHERS)
SILICONE
OPEN
PART NO.
A96491
REV.