Digikeijs DR4088CS Instrukcja obsługi - Strona 6
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Konwerter mediów Digikeijs DR4088CS. Digikeijs DR4088CS 15 stron. Feedback module
Również dla Digikeijs DR4088CS: Instrukcja obsługi (11 strony), Podręcznik (8 strony), Instrukcja obsługi (14 strony), Instrukcja obsługi (12 strony)
DR4088LN-CS / GND / OPTO
3.0 Programming
First, something fundamental about LocoNet®:
•
The LocoNet® is a universal bus system.
•
The LocoNet® supports a maximum of 2048 feedback addresses.
•
The addresses are always stored in the feedback module.
•
The LocoNet® can be set up as a tree, star or bus (line) network. A combination of the individual topologies is permissible.
•
Please note that a ring structure is not permitted.
DR DR4088LN-xx does not have LNCV's as known from other manufacturers. Therefore no LNCV's can be read out or changed.
The DR4088LN-xx must only be "told" the start address and the number of feedbacks via a switch command!
3.1 Programming DR4088LN-xx without further DR4088 on the S88N
3.1.1 Programming with the DR5000
1.
Connect the DR5000 to the DR4088LN-xx to be programmed.
2.
(Normally it is not necessary to disconnect other feedback modules from LocoNet®.
3.
Open the DR5000 Tool.
4.
First the DR4088LN-xx must be assigned the start address.
5.
Open the turnout control panel that contains the desired start address that the DR4088LN-xx is to receive.
6.
Press the programming button on the DR4088LN-xx. The green LED starts flashing to indicate that the DR4088LN-xx is in programming mode.
7.
To assign the start address, switch the turnout address e.g. 1 once (i.e. only red or green!).
8.
The green LED on the DR4088LN-xx now flashes in a different cycle to signal that the DR4088LN-xx next expects the number of feedback signals. The
number of feedback units is again sent to the DR4088LN-xx via a turnout command.
9.
Normally, if no DR4088 (S88) is connected to the DR4088LN-xx, this is address 16.
10.
In the DR5000 tool, call the turnout control panel which contains the address corresponding to the number of feedback signals.
11.
Normally, this is address 16. Again, only red or green switching applies here.
12.
The DR4088LN-xx automatically terminates the programming mode and is now programmed with the start address and the number of feedbacks.
.
Important!
When using the LN or RB module, the ext88N IN number of 16 and 8 input modules must be set to 0 on the DR5000. This can be checked if in the feedback
monitor row 1 and row 9 are white with blue and not red!
www.digikeijs.com
® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
2021-04-21
P 6