Digikeijs DR5033 Instrukcja obsługi - Strona 8

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Przedłużacz Digikeijs DR5033. Digikeijs DR5033 18 stron. 3-ampere, h-bridge dcc booster
Również dla Digikeijs DR5033: Podręcznik (10 strony), Instrukcja obsługi (18 strony)

Digikeijs DR5033 Instrukcja obsługi
DR5033 DIGIBOOST

4.0 Connec on examples

The connec on examples shown here represent only a small part of the possibili es for connec ng the DR5033 to different control panels. Please note that
there are of course further possibili es and special cases which cannot be shown here!
4.1 Important notes on using the DR5033.
The configura2on is done via LocoNet®.
The DR5033 can be used with control panels that use an H-bridge to generate track signals.
The same voltage must be set on the power supply units of the boosters and control panels.
When using the CDE booster connec2on on the DR5033, it must be ensured that the CDE connec2on of the central unit meets the specifica2ons of Fa. Lenz®.
Opera2on of the DR5033 in conjunc2on with control panels (e.g. Uhlenbrock®, Piko® Smart ControllerLigth®, etc.) which operate according to the "common
ground principle" is not possible on the same circuit. This can lead to damage to components. Even a busbar separa2on on both sides is not sufficient! Please
note connec2on example 4.9.
The tracks must always be separated on both sides between the booster and central areas.
The maximum number of boosters on the Roco® B-Bus® is limited to four.
The transi2on voltage between the booster ranges must always be less than 0.8 Volt. This can easily be checked with a mul2meter (sePng the measuring
range to AC alterna2ng voltage). Both rail separa2ons must always be checked. If the value of 0.8 Volt is exceeded, the input voltage of the booster or the
voltage sePng of the central unit must be adjusted.
Central
www.digikeijs.com
® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
Stand 2019-10-14
Booster
DR50333
The displayed measured value must not
exceed 0.8 Volt!
Always check both track separa2ons!
P 8