HOW TO SET THE CONTROL, continued
FOR PROBE COOK OPERATION:
Press the SELECT button to choose the probe
mode.
PROBE TEMPERATURE:
1. Press the PROBE/TIME button. The
display will show the probe setpoint
temperature.
2. Use the UP and DOWN arrows to set the
desired temperature.
3. Press the SET button to enter the
temperature into the control.
NOTE: Press the OVEN TEMP button at any
time to view the actual oven temperature.
NOTE: The control will beep when the probe
setpoint temperature has been reached and then
will automatically switch to HOLD mode. The
display will then show the hold setpoint
temperature.
To manually end the COOK/RETHERM,
PROBE, or HOLD mode:
Press the STOP button during any of the above
modes and the control will end that mode. If in
the Cook/Retherm or Probe mode, the control
will automatically switch into the HOLD mode.
HOW TO OPERATE WITH FOOD:
Manual (Timed mode) Operation
See "HOW TO SET CONTROL" (on page 4)
for programming instructions.
1. Push power switch to "ON".
2. Press the SELECT button and choose the
TIMED mode.
3. Press the COOK button and set to
desired temperature.
4. Press the PROBE/TIME button and set
to the desired time.
5. Press the HOLD button; set desired
temperature.
6. Place the food into oven. Close door and
double check cooking time and
temperatures. Then press the START
button to start the cooking/retherm cycle
and the Cook LED will light up.
OPERATING INSTRUCTIONS, continued:
Undercounter Ovens
Rev. 1 (9/04)
7. The oven will beep and automatically
switch to the HOLD mode at the end of
the cooking cycle. The Cook lamp will
go out and the Hold lamp will light up.
Probe Cooking
See "HOW TO SET CONTROL" (on page 5)
for programming instructions.
1. Push power switch to "ON".
2. Press the SELECT button and choose the
Probe mode.
3. Insert the probe jack into the receptacle
located inside the oven top, near the
fans. The probe temperature display will
show the digital temperature of the
probe.
4. Put sanitized probe into center of food
product. Make sure food is in the center
of the pan and the pan is centered in the
oven.
5. Press the start button. The cook lamp
will light up and the display will show
the internal temperature of the food
being cooked.
NOTE: Do NOT change the mode of the
controls (probe or timed) while oven is
operating in a Cook/Retherm cycle. Oven must
be in the HOLD cycle to change the timer or
probe operation.
HOW TO SET HOLD-ONLY MODE:
1. Push power switch to "ON".
2. Press the STOP button and the oven will
switch to HOLD cycle.
3. Press the HOLD button and set the
desired hold temperature.
HOW TO SHUT DOWN OVEN:
Push switch to "OFF".
CAUTION: Ventilating fans will continue to
run until the cabinet is cool. Do NOT
disconnect the power supply to the cabinet
while the ventilating fan is still operating.
FL-2292