B: Setting Minimum Brightness
The minimum brightness level provided by the dimmer can be set to suit specific lamps and/or customer requirements.
For the majority of lamps a minimum level as low as 0% can be set if required. However, some lamps can become unstable at
low dimming levels, in particular CFL's.
If lamps become unstable at low dimming levels, they typically flicker or pulse on/off. The dimmer allows the minimum
brightness to be set to a level above the point at which the lamp flickers/pulses.
Step 1
Enter into the dimmer Setup Mode - See PART A (page 9)
Step 2
Click the dimmer push button twice
Step 3
LED will blink 2 times
Note: To cancel/exit do nothing for 30 seconds
Note: If more than one dimmer is connected to the same load (see pages 5-7), all
dimmers connected to this load will now blink 2 times
Step 4
Adjust dial to required MINIMUM brightness level
Note: If more than one dimmer is connected in parallel (see pages 5-7), wait for 3
seconds for the other connected dimmer to learn the new minimum level
Note: To cancel/exit do nothing for 30 seconds
Step 5
Click once to save & exit
Note: If more than one LEDsmart
brightness levels only needs to be set in one device. The setting is automatically
saved to all other devices connected in parallel
+
device is connected in parallel, the minimum
Push Button Dimmer/Switch
10