D: Setting Advanced Timer Mode
The advanced timer mode provides an optional advanced warning to the user that the lights will shortly turn off automatically.
When the advance timer is enabled, at time out the lights are dimmed to 50% over a 4 second period and are held at this 50%
level for 5 minutes. After this 5 minutes, the lights are turned off automatically.
Step 1
Enter into the timer Setup Mode - See PART A
Step 2
Click the push button 4 times
Step 3
The LED Indicator will blink 4 times
Note: To cancel/exit do nothing for 30 seconds
Step 4
To enable the advanced timer mode
Push and hold the button until the lamps(s) turn ON
To disable the advanced timer mode
Push and hold the button until the lamps(s) turn OFF (default)
Note: To cancel/exit do nothing for 30 seconds
Step 5
Click once to save & exit
Note that during this Advanced Timer 5 minute warning period:-
• The LED indicators will blink at a faster rate
• A tap of the push button will restore the load to 100%
ON and the timer will restart
• A long press of the push button will turn the load OFF.