disabled. Combo ports are indicated by the presence of a bar on the
panel that connects them, as shown in the following example:
• The LEDs of the corresponding RJ-45 port light to respond to the SFP
interface traffic.
SG300-10SFP ports 1—8 are dedicated SFP ports. Their LED
N
OTE
status and indication are the same as on the RJ-45 ports.
Front Panel LEDs
System LED—(Green) Lights steady when the switch is powered on, and
flashes when booting, performing self tests, and acquiring an IP address. If
the LED flashes Amber, the switch has detected a hardware failure.
LINK/ACT LED—(Green) Located on the left of the port. Lights steady
when a link between the corresponding port and another device is
detected. Flashes when the port is passing traffic.
PoE (if present)—(Amber) Located on the right of the port. Lights steady to
indicate that power is being supplied to a device attached to the
corresponding port.
100M LED (if present)—(Green) Located on the right of the port. Lights
steady when another device is connected to the port, is powered on, and a
100 Mbps link is established between the devices. When the LED is off, the
connection speed is under 100 Mbps or nothing is cabled to the port.
Gigabit LED (if present)—(Green) Located on the right of the port. Lights
steady when another device is connected to the port, is powered on, and a
1000 Mbps link is established between the devices. When the LED is off,
the connection speed is under 1000 Mbps or nothing is cabled to the port.
SFP (if present)—(Green) Located on the right of a GE port. Lights steady
when a connection is made through the shared port. Flashes when the port
is passing traffic.
Reset Button
The switch can be reset by inserting a pin or paper clip into the reset
opening. See
"Returning the Device to the Factory Default Settings"
details.
300 Series Managed Switches
for