Fiap Turbo Active Podręcznik - Strona 4

Przeglądaj online lub pobierz pdf Podręcznik dla Systemy filtracji wody Fiap Turbo Active. Fiap Turbo Active 18 stron.
Również dla Fiap Turbo Active: Podręcznik (10 strony)

Fiap Turbo Active Podręcznik
FIAP Turbo Active
consists of exchanging or replacing the defective parts. Incorrect use shall void all claims to warranty.
FIAP is not liable for any damage resulting from using the Turbo Active. Subject to changes.
Delivery
Check that your Turbo Active is complete. On delivery, the Turbo Active is largely assembled and
equipped with a 2-meter-lang flexible hose.
Accessories
You need a pump to use the FIAP Turbo Active. Place the pump as far as possible from the water
drain pipe of the Turbo Active. Always follow the instructions for the pump.
Parts of the Turbo Active
1
Foam-reactor cover
2
Cover
3
Dirt extract drain pipe
4
Drain socket
5
Hose Ø=32 mm
6
Inside cover
7
Regulation unit
8
Tank
9
Venturi jet
10 Foam-reactor
Technische Änderungen vorbehalten. Für Druckfehler übernehmen wir keine Haftung. WEEE-Reg. Nr.: DE78152045
FIAP GmbH, Jakob Oswald Str. 16, 92289 Ursensollen
Tel: 09628 9213 0; Fax: 09628 9213 30;
7
www.fiap.com
FIAP Turbo Active
Regulation
Water level too high!
Turn regulator to the right.
Problem:
Cause:
Tub is not being filled with water
Pump is broken
Inlet hose of the pump is off
Hole in venturi jet is blocked
Regulation unit is stuck
Regulation unit is dirty
Regulation unit is frozen
The water level has to be raised until
Air intake of the venturi jet is blocked
just under the edge of the tub
Pump is blocked
Pump capacity too low
No foam bubbles are rising in the tube
Air can not escape from the foam-reactor
of the foam-reactor
The Turbo Active cannot be adjusted
Pump is too strong –
causing too much turbulence in the tub.
Water coming out of the connecting
Tub is cracked
screws of the inside cover
Screws have not been fastened tight enough
Seal is on the wrong side
Water coming out of the nut at the
Nut is not been fastened tight enough
Regulation unit
Water coming out of the transition
Hose clip is not tight enough
between the hose and the venturi
Hose has cracked
The dirty water is not draining away
Water quality has improved so that less foam
is formed
Technische Änderungen vorbehalten. Für Druckfehler übernehmen wir keine Haftung. WEEE-Reg. Nr.: DE78152045
FIAP GmbH, Jakob Oswald Str. 16, 92289 Ursensollen
Tel: 09628 9213 0; Fax: 09628 9213 30;
Water level too low!
Turn regulator to the left.
Correction:
Replace the pump
Attach the hose
Clean the venturi jet
Clean the regulation unit
thoroughly
Defrost the regulation unit
Clean the air intake
Clean the pump
Ask your dealer for a
suitable pump
Clean the drain pipe of of
the reactor and ensure that
the end of the drain pipe is
not under water
Ask your dealer for a
suitable pump
Replace the tub
Fasten screws so that no
more water escapes
The seals should be on the
outside of the tub
Tighten the nut
Slowly tighten the hose clip
until no more water escapes
Replace the hose
Adjust
8
www.fiap.com