Cisco AJ732A - MDS 9134 Fabric Switch Uwaga dotycząca wydania - Strona 39

Przeglądaj online lub pobierz pdf Uwaga dotycząca wydania dla Przełącznik Cisco AJ732A - MDS 9134 Fabric Switch. Cisco AJ732A - MDS 9134 Fabric Switch 44 stron. Converged network switches for nx-os 4.0(1a)n1(1)
Również dla Cisco AJ732A - MDS 9134 Fabric Switch: Podręcznik konfiguracji (49 strony), Uwaga dotycząca wydania (48 strony), Uwaga dotycząca wydania (44 strony), Uwaga dotycząca wydania (36 strony), Uwaga dotycząca wydania (26 strony), Uwaga dotycząca wydania (22 strony), Skrócona instrukcja obsługi (14 strony), Uwaga dotycząca wydania (3 strony)

Cisco AJ732A -  MDS 9134 Fabric Switch Uwaga dotycząca wydania
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Workaround: Use the show ivr internal vdri vsan vsan-id domain domain command to determine
which border switch is exporting the virtual domain. Then on any of the border switches that is
exporting the virtual domain, enter the following command for each device that has a partial FCNS
entry:
switch(config)# ivr device pwwn pwwn fcns register vsan vsan-id
In this example, pWWN is the port pWWN of the device and vsan-id is the VSAN that contains the
incomplete FCNS entries.
CSCin95789
Symptom: When you configure Cisco Traffic Analyzer to capture traffic on one or more interfaces
on a Windows platform, the configuration web page might not show that the interface has been
selected for traffic capture even though traffic capture on that interface is enabled.
Workaround: Check the logs to clarify that the correct interface has been selected.
CSCsd21187
Symptom: If an iSNS client tries to register a portal separately after registering the network entity
and storage node object with the Cisco MDS iSNS server, the portal registration might fail.
Workaround: Register the portal at the same time as the network entity and storage node object
registration.
CSCse31881
Symptom: If there are IP over Fibre Channel (IPFC) interfaces configured on an SSM, you might
experience issues if you downgrade from SAN-OS Release 3.x to Release 2.x.
Workaround: Before downgrading, remove the IPFC interface on the module and then recreate the
IPFC interface after the downgrade is complete.
CSCse47687
Symptom: If IP ACLs are applied to any IP Storage Gigabit Ethernet port, implicit deny does not
take effect.
Workaround: Configure explicit deny on the port.
CSCsg19148
Symptom: Time zone changes that are executed on an MDS switch do not take effect on the 12-port,
24-port, and 48 port 1-Gbps/2-Gbps/4-Gbps Fibre Channel modules, and on the 4-port 10-Gbps
module. This issue occurs in SAN-OS Releases 3.0(1), 3.0(2), 3.0(2a), and 3.0(3).
Time zone changes that are executed on an MDS switch do not take effect on the 16-port or 32-port
1-Gbps/2-Gbps module, on the 4-port or 8-port Gigabit Ethernet IP services module, the MPS 14/2
module, and on the SSM. This issue occurs in SAN-OS Release 3.0(3).
This issue has no effect on functionality. However, debug messages and syslogs from the MDS
switching modules have incorrect timestamps if the time zone is configured on an MDS switch.
Workaround: None.
CSCsg19303
Symptom: Graceful shutdowns of ISLs are not supported for IVR traffic.
Workaround: Increase the fspf cost on the link before it is shut down, so that traffic will flow
through an alternate path.
CSCsi66310
Symptom: The management port on MDS switches supports one user-configured IPv6 address, but
does not support autoconfiguration of an IPv6 address in Cisco SAN-OS Release 3.2(1).
OL-14116-01
Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.2(1)
Caveats
39