Cisco AP776A - Nexus Converged Network Switch 5020 Uwaga dotycząca wydania - Strona 21

Przeglądaj online lub pobierz pdf Uwaga dotycząca wydania dla Przełącznik Cisco AP776A - Nexus Converged Network Switch 5020. Cisco AP776A - Nexus Converged Network Switch 5020 26 stron. Cisco nexus 5000 series release notes release 4.1(3)n1(1) (ol-16601-01 h0, july 2009)
Również dla Cisco AP776A - Nexus Converged Network Switch 5020: Uwaga dotycząca wydania (48 strony), Uwaga dotycząca wydania (44 strony), Uwaga dotycząca wydania (22 strony), Skrócona instrukcja obsługi (14 strony), Uwaga dotycząca wydania (3 strony), Uwaga dotycząca wydania (26 strony)

Cisco AP776A - Nexus Converged Network Switch 5020 Uwaga dotycząca wydania
S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m
Resolved Caveats—Cisco NX-OS Release 4.0(0)N1(2a)
OL-16601-01
CSCsr39670
Symptom: Although SNMP notification is enabled on the switch, traps for the power supply and fan
modules are not received.
Workaround: None.
CSCsr47531
Symptom: When a VSAN is configured as SPAN source, traffic from all the member ports is
spanned to the SPAN destination port. When a switch is rebooted, the VSAN SPAN source remains
in the down state.
Workaround: Delete and add the VSAN sources for the SPAN session.
CSCsu08988
Symptom: Telnet access is available only after reloading the Nexus 5020 switch with the no telnet
server enable command running.
Workaround: Execute the no telnet server enable command once again after reload even if the
command is saved in the startup-config. Additionally, you can also apply filters to the SVI to allow
only trusted hosts to communicate with the system.
CSCsu32247
Symptom: The Nexus 5000 Series switch executes the power-on self-test (POST) at bootup to
validate hardware integrity of the ASICs. When a Fibre Channel port is connected to a host bus
adapter (HBA), the HBA driver can trigger a signal loss that causes a false failure to be reported by
POST for one of the ASICs. As a result, all the ports serviced by the ASIC on the GEM are marked
for hardware failure.
Workaround: Do not connect HBAs to the FC expansion modules.
CSCsu40126
Symptom: When the Nexus 5000 Series switch is configured to operate in the N-port virtualization
(NPV) mode, the LOGOs received over the server port are not processed properly. This results in
stale Fibre Channel IDs at the switch.
Workaround: Perform shut and no shut command operations on all the server ports to clear the
stale state on the NPV switch.
CSCsm66194 and CSCsr66209
Symptom: Logins may not be uniformly balanced across all available border ports when the Nexus
5000 series switch operates in the NPV mode under conditions such as the following:
The switch is reloaded.
NPIV is disabled and re-enabled on the NPV core-switch.
The NPV core-switch is reloaded.
A new NP link is added.
Workaround: Perform shut and no shut command operations on all the server ports to rebalance
the logins.
CSCsu25775
Symptom: When the Nexus 5020 Series switch is connected to a 110 V power supply, the following
problems occur:
Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a)
Caveats
21