This parameter determines time needed for roller blinds to reach the bottom.
For modes with positioning value is set automatically during calibration, otherwise, it must be
set manually.
Size: 4 Byte, Default Value: 6000
Setting
1 - 90000 (0.01 – 900.00s, every 0.01s) – movement time
Technical Data
Dimensions
Weight
EAN
IP Class
Voltage
Load
Device Type
Generic Device Class
Specific Device Class
Firmware Version
Z-Wave Version
Z-Wave Product Id
Frequency
Maximum transmission power 5 mW
Supported Command Classes
Basic
Application Status
Switch Multilevel
Meter
Crc 16 Encap
Association Grp Info
Device Reset Locally
Central Scene
Zwaveplus Info
Multi Channel
Supervision
Configuration
Alarm
Manufacturer Specific
Powerlevel
Description
42.50 x 38.25 x 20.30 mm
27.83 gr
5905279987197
IP 20
230 V
1,7 A
Roller Shutter
Multilevel Switch
Motor Control Device (B)
05.00
06.02
0x010f.0x0303.0x1000
Europe - 868,4 Mhz