Sharp AQUOS LC-37D43U Instrukcja serwisowa - Strona 2
Przeglądaj online lub pobierz pdf Instrukcja serwisowa dla TELEWIZOR LCD Sharp AQUOS LC-37D43U. Sharp AQUOS LC-37D43U 6 stron. Lcd color
Również dla Sharp AQUOS LC-37D43U: Specyfikacje (2 strony), Instrukcja serwisowa (6 strony), Instrukcja serwisowa (22 strony), Instrukcja obsługi (11 strony)
LC-37D42U/LC-37D43U/LC-C3742U
LC-37D42U (A)
OUTLINE AND ADJUSTMENT
[1] Outline
In this Service Manual, only parts in the LCD module are shown. For the other points, refer to the LC-37D42U/LC-37D43U/LC-C3742U
(S06X9LC32D42U/SX6Y9LC37D43U/SX6Y7LCC3742U) Service Manual.
New panel modules are incorporated in LC-37D42U/LC-37D43U/LC-C3742U with the Serial No. "****51112~".
How to distinguish the model labels of new and old panel modules.
As to the new panel module, the mark A is printed on the model label.
Old panel module
No A mark on the right side of the model name
Example
[2] Adjustment
When replacing the LCD control PCB, follow these steps to adjust VCOM.
1) Remove the wire from the LCD control PCB CN3.
2) Connect a wire of the VCOM adjustment jig (electronic volume adjustment BOX) to CN3 (see Fig. 1).
3) Turn on the TV set.
4) Turn on the jig (connect to the AC).
5) Enter the process mode to display the item "LCD TEST PATTERN OFF" (see Fig. 2).
6) Press the volume up key once to display a flicker pattern.
7) Press the jig's UP/DOWN switch while looking at the screen to adjust the point so that the flicker is minimized (see Fig. 3).
8) After completing adjustment, press the WRITE switch and make sure the lamp of the WRITE button goes out. (Writing is complete when the lamp
goes out.)
9) Turn off the jig (turn the AC off).
10)Turn off the TV set.
11)Remove the jig's wire connected to CN3.
12)Reconnect the wire of the set to CN3.
Jig connection
Fig. 1 Jig connecting location
Service Manual
New panel module
A mark on the right side of the model name
No Mark
Fig. 2 Test pattern selection screen
i
Example
Fig. 3 VCOM adjustment jig (RUNTZA059WJZZ)
A