DIGISYSTEM APS20201 Instrukcja obsługi - Strona 4
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Zasilanie DIGISYSTEM APS20201. DIGISYSTEM APS20201 9 stron. Variable frequency vibrators power supply
TECHNICAL SPECIFICATIONS
Power supply:
Output voltage:
Output compensation:
Output frequency:
Current:
Fuses:
Voltage output:
Remote commands:
Mechanical protection:
EMI Protection:
Wiring:
Dimensions:
Weight:
230Vac ± 15%, frequency 50 or 60 Hz
from 50 to 220Vca (with power supply 230Vca)
compensation of power supply variations
from 3,0 to 199,9 Hz in step of 0,1 Hz
maximum current 5 Amperes peak (about 2,5 Arms) limited
from a circuit with autoreset
4 A fast action 250Vac; dimensions 5x20
soft-start with ramp of about 0,5 seconds
start/stop with external voltage PNP
(15 ÷ 30 Vdc, current 10 mA)
external potentiometer
voltage reference 0 ÷ 5 Vdc
start/stop NPN
IP 50 (on request IP 54)
meets following regulations: LVD CEI EN60439-1
If observed wiring instructions.
fairlead and wire with shuko for mains input and HAN-3A
Harting connector for vibrator output.
169 x 120 x 76 mm (height, breadth, depth)
(90 mm must be provided in low side for connector insertion)
1,2 Kg
4
optocoupled
see page 9
see page 9
see page 9
EMC CEI EN50082-2
EMC CEI EN50081-2