Sharp 92L2390137W010 Instrukcja obsługi - Strona 26
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla System stereo Sharp 92L2390137W010. Sharp 92L2390137W010 28 stron.
Troubleshooting
CD-BK137W
„ If trouble occurs
When this product is subjected to strong external interference (mechanical shock,
excessive static electricity, abnormal supply voltage due to lightning, etc.) or if it is
operated incorrectly, it may malfunction.
If such a problem occurs, do the following:
1 Set the unit to the stand-by mode and turn the power on again.
2 If the unit is not restored in the previous operation, unplug and plug in the unit,
and then turn the power on.
Note:
If neither operation above restores the unit, clear all the memory by resetting it.
„ Clearing all the memory (reset)
1 Press the ON/STAND-BY button to enter the power stand-by mode.
2 Whilst pressing down the
ton, press the ON/STAND-BY button until "CLEAR AL" appears.
Caution:
This operation will erase all data stored in memory including clock, timer settings,
tuner preset, and CD programme.
„ Before transporting the unit
1 Press the ON/STAND-BY button to turn the power on.
2 Press the CD button.
3 Press the
OPEN/CLOSE button to open the disc tray.
Remove all discs from the unit.
4 Press the
OPEN/CLOSE button to close the disc tray.
Make sure that "NO DISC" is displayed.
5 Press the ON/STAND-BY button to enter the stand-by mode, and then unplug
the AC power lead from the wall socket.
E-25
ENGLISH
/
button and the EQUALIZER/X-BASS/DEMO but-
Maintenance
„ Cleaning the tape-handling parts
z Dirty heads, capstans or pinch rollers can cause poor sound and tape jams. Clean
these parts with a cotton swab moistened with commercial head/pinch roller
cleaner or isopropyl alcohol.
z When cleaning the heads, pinch rollers, etc., unplug the unit which contains high
voltages.
TAPE 1
TAPE 2
Playback head
Capstan
Pinch roller
z After long use, the deck's heads and capstans may become magnetised, causing
poor sound. Demagnetise these parts once every 30 hours of playing/recording
time by using a commercial tape head demagnetiser. Read the demagnetiser's
instructions carefully before use.
„ Cleaning the cabinet
Periodically wipe the cabinet with a soft cloth and a diluted
soap solution, then with a dry cloth.
Caution:
z Do not use chemicals for cleaning (petrol, paint thinner,
etc.). It may damage the cabinet finish.
z Do not apply oil to the inside of the unit. It may cause
malfunctions.
01/8/28
CD-BK137W(X)E3.fm
B
C
A
E
B
C
D
Erase head
Recording/Playback head