Problem
(DM-TX-4K-302-C
only) Component
or composite video
may not be
displayed, may be
intermittent, or
may be missing
color.
The transmitter
does not remain
powered on.
The SIMPL
Windows program
is not operational.
The video flickers
or drops when the
transmitter is
touched or when
metal in the
vicinity of the
device is touched.
NOTE:
If, for any reason, the factory default settings of the DM-TX-4K-202-C or
DM-TX-4K-302-C must be restored, do the following: From the Tools menu in the Crestron
Toolbox software, select Text Console and enter the following command:
restore y
12 • DM-TX-4K-202-C and DM-TX-4K-302-C
Possible Cause(s)
The VGA breakout cable connections are
faulty.
When the transmitter is not
powered by the optional
PW-2407WU power pack (sold
separately), the DM OUT port is
not connected to a PoDM+,
PoDM, HDBaseT PoE+, or
HDBaseT PoE power sourcing
equipment (PSE) port that is
required to power the
transmitter.
In a configuration in which a DigitalMedia
switcher is not used, the IP table is not
set properly.
If the transmitter connects to a
DigitalMedia switcher, the transmitter
does not connect to the correct DM input
port of the switcher.
The transmitter is not properly grounded.
Corrective Action
Ensure that the VGA
breakout cable connections
are correct.
Ensure that the DM OUT port
is connected to an
appropriate PSE port when
not being powered by the
optional PW-2407WU power
pack.
Verify that the IP table is set
properly in System Info in the
Crestron Toolbox software.
Ensure that the transmitter
connects to the correct DM
input port of the switcher.
Ensure that the transmitter is
properly grounded.
Supplemental Guide — Doc. 7932B