CP4-R
4-Series Control Processor for Crestron Pyng® OS 2
The Crestron® CP4-R 4-Series control processor provides a secure, high-performance, rack-mountable control processor with an embedded
Crestron Pyng® OS 2 operating system. The CP4-R is designed exclusively to function as the core of a Crestron Pyng home automation system, and
features enhanced processing power to handle larger home automation, home theater, multiroom video, and MDU (multidwelling unit) applications.
Check the Box
Item
CP4-R
Bracket, Rack Ear, 1U (P/N 2032122)
Cable, USB 2.0, A - B, 6 ft (1.83 m) (P/N 2014966)
Connector, 3-Pin (P/N 2003575)
Connector, 4-Pin (P/N 2003576)
Connector, 5-Pin (P/N 2003577)
Connector, 8-Pin (P/N 2003580)
Connector, 9-Pin (P/N 2003581)
Foot, 0.5 in. x 0.5 in. x 0.23 in., Rubber, Black (P/N 2002389)
IR Emitter, with Terminal Block Connector, IRP2 (P/N 4500152)
Power Cord, 5 ft 10 in. (1.78 m) (P/N 2042043)
Power Pack, 24 VDC, 2.5 A, 100-240 VAC (P/N 2045873)
Install the Device
The CP4-R may be mounted into a rack or placed onto a flat surface.
Mount into a Rack
The CP4-R occupies 1U of rack space. Use a #1 Phillips screwdriver to remove the required screws from the CP4-R assembly (shown in the
illustration below), and then attach the two included rack ears with the removed screws. Mount the CP4-R into the rack with four mounting screws
(not included).
Place onto a Flat Surface
When the CP4-R is placed onto a flat surface or stacked with other equipment, attach the four included feet near the corners on the underside of
the CP4-R.
CP4-R
Rack ears (2)
CP4-R assembly screws
Connect the Device
Make all necessary connections to the CP4-R as shown in the illustration below.
RELAY OUTPUT (1–8):
IR - SERIAL (1–8):
To contact closure
To TLL/RS-232
devices
devices
Qty
1
2
1
2
1
I/0 (1–8):
To controllable
1
devices
4
1
NOTE:
Ensure that the included SD card is seated fully in the MEMORY slot prior to powering on the CP4-R.
Observe the following when connecting the CP4-R:
4
•
Use Crestron power supplies for Crestron equipment.
4
•
The CP4-R may be powered with the included 24 VDC power supply or via Cresnet® network power with the NET 4-pin terminal block port.
1
•
The included cables may not be extended.
1
•
Connect the chassis ground lug to a known earth ground circuit (for example, building steel) to ensure that the CP4-R is grounded properly.
•
Apply power after all connections have been made.
COM 1 Connections
Port
RS-232
RS-422
1
G
GND
GND
TX
TX (from CP4-R)
TX- (from CP4-R)
RX
RX (to CP4-R)
RX+ (to CP4-R)
RTS
RTS (from CP4-R)
TX+ (from CP4-R)
CTS
CTS (to CP4-R)
RX- (to CP4-R)
1. RS-422 transmit and receive are balanced signals that require two lines plus a ground in
each direction. RXD+ and TXD+ should idle high (going low at start of data transmission).
RXD- and TXD- should idle low (going high at start of data transmission). If necessary,
RXD+/RXD- and TXD+/TXD- may be swapped to maintain correct signal levels.
2. A ground terminal connection is recommended but not required.
Download the Crestron Pyng Configuration App
The Crestron Pyng configuration app may be downloaded onto an Apple® iPad® device from the App Store® online store.
NOTES:
•
An Apple ID is required to download the Crestron Pyng configuration app. Refer to
https://support.apple.com/kb/HT2731
for help with creating an Apple ID.
•
For a comprehensive list of iOS® hardware and software versions that are compatible with the Crestron Pyng configuration app, refer to OLH
article 5655 at https://support.crestron.com/app/answers/detail/a_id/5655.
To download the Crestron Pyng configuration app:
1.
Tap the App Store icon
on the iPad device home screen.
2.
Tap the search field, and enter the search term "Crestron Pyng."
3.
Tap Search.
4.
Tap the Crestron Pyng app icon
.
5.
Follow the prompts to download the app to the device.
COM2/COM3:
USB:
NET:
To serial
controlled
To storage
To any Cresnet®
devices
devices
network device
COM1:
MEMORY:
LAN:
24V, 2.0A:
To serial
100/1000BASE-TX
SD-compatible
From AC
controlled
card slot
Ethernet to LAN
power pack
devices
RS-485
GND
2
TX-/RX-
Not used
TX+/RX+
Not Used
Ground