Bitstream RSMUX3-F0-M Skrócona instrukcja obsługi - Strona 3
Przeglądaj online lub pobierz pdf Skrócona instrukcja obsługi dla Konwerter mediów Bitstream RSMUX3-F0-M. Bitstream RSMUX3-F0-M 5 stron. Fiber optical converter rs232/rs422/rs485
Quick start manual, a detailed manual is on the enclosed CD or can be downloaded from
2
Voltage range for version 120-260V DC and 100-240V AC
–
– Current consumption 230V AC/ 200mA
– Voltage polarity – the polarization on power connector is very important
– Screw connection for power supply - triple block terminal, screwed connector for 3 mm2 diameter
cable
3
The device is factory set to active RS485 (2W) interface (DIP-SWITCHA - OFF default
configuration) for all serial ports.
4
The unit parameters are configured using the three DIP switches on the rear of the unit. They are
used to configure the RING, serial interface parameters and to switch the operating modes of the
device.
Configuration of the RING and SLOW MODE
1
2
OFF
ON
ON
OFF
-
-
-
-
OFF
OFF
ON
OFF
OFF
ON
ON
ON
REV.
1.04
company's website www.bitstream.com.pl/en/
P
OWER SUPPLY
F
S
-
IRST
TART
UP
D
EVICE CONFIGURATION
Img.5. Rear panel view
RING CONFIG
3
OFF
OFF
-
-
ON
ON
ON
ON
RSMUX3-FO SHORT USER MANUAL
4
NU
MAS.
NU
SL.
OFF
ON
SM
NU
64 D.
NU
16 D.
NU
8 D.
NU
4 D.
WITH
PROTECT.
NORMAL MODE
SLOW MODE
WITHOUT
PROTECT.
2019.05.17
3/5