5 Useful information
5.1.3
System jobs
The following describes the jobs that are implemented in this example. Note that
you must wait for the respective response telegram (reader response time) before
you can send new request telegrams.
syscmd_reset: Reset the SIMATIC RF1070R reader
Table 5-1 job telegram
Byte
Value
0
0x0C
0x1C
1
0x00
2
0xC3
3...4
0x00
5
0xC2
Table 5-2 response telegram with no errors
Byte
Value
0
0x0C
0x1C
1
0x00
2
0xC3
3...4
0x00
5
0xC2
syscmd_set_port: Setting the SIMATIC RF1070R reader's LED
Table 5-3 Job telegram
Byte
Value
0
0x0C
0x1C
1
0x00
2
0x07
3
0x02
4
0x00
5
0x00
6
0xXX
Reading out UID with SIMATIC RF1070R
Article ID: 109780625,
V1.0,
Without checksum
With checksum
DevCode of the command set containing the command to be called.
CmdCode of the command to be called.
Parameter length (0 bytes)
Optional checksum (when the value "0x1C" is set in byte 0).
Without checksum
With checksum
DevCode of the command set containing the command to be called.
CmdCode of the command to be called.
Parameter length
Optional checksum (when the value "0x1C" is set in byte 0).
Without checksum
With checksum
DevCode of the command set containing the command to be called.
CmdCode of the command to be called.
Parameter length
port_msk:
•
0x00: LED and acoustic signal transducer
•
0x01: LED lit green
•
0x02: LED lit red
•
0x03: LED lit orange
•
0x04: Acoustic signal transducer
•
0x05: Acoustic signal transducer and LED lit green
•
0x06: Acoustic signal transducer and LED lit red
•
0x07: Acoustic signal transducer and LED lit orange
09/2020