Siemens SIMOGEAR 2730 Instrukcja montażu i obsługi - Strona 36

Przeglądaj online lub pobierz pdf Instrukcja montażu i obsługi dla Urządzenia przemysłowe Siemens SIMOGEAR 2730. Siemens SIMOGEAR 2730 48 stron. Geared motor with rotary encoder for safety-relevant applications

Ensuring functional safety
4.5 Technical data
4.5.2.2

Rating plate SIMOGEAR geared motors without a UL/CSA design

SIEMENS
Figure 4-1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Frequency 1
19
20
21
22
Frequency 2
23
24
25
26
Motor and brake data
27
28
29
34
M
Example of a SIMOGEAR rating plate for geared motors without UL-CSA
Data matrix code
Underlying standard
Serial number
CE marking or other marking, if required
Article number
Type designation with marking of the (functionally safe) rotary encoder
Mounting position
Geared motor type
Degree of protection acc. to IEC 60034‑5
Ventilation type acc. to IEC 60034‑6
Weight m in kg
Ambient temperature
Customer ID
Motor operating mode
Oil quantity in l, main gearbox / intermediate gearbox
Oil grade
Oil viscosity ISO VG class according to DIN 51519 / ISO 3448
Total transmission ratio i
Rated frequency f in Hz
Gearbox output speed n
Geared motor output torque T
Service factor f
B
Rated frequency f in Hz
Gearbox output speed n
Geared motor output torque T
Service factor f
B
Phase number and type of current for the motor
Temperature class Th. Cl.
Thermal motor protection
SIEMENS
 in rpm
2
 in Nm
2
 in rpm
2
 in Nm
2
Operating Instructions, 01/2024, A5E53220857A/RS-AA
SIMOGEAR functionally safe rotary encoder