Cisco WS-X45-SUP9-E Uwaga dotycząca instalacji i konfiguracji - Strona 13
Przeglądaj online lub pobierz pdf Uwaga dotycząca instalacji i konfiguracji dla Przełącznik Cisco WS-X45-SUP9-E. Cisco WS-X45-SUP9-E 22 stron.
What to Do Next
Install the blank slot cover or a replacement supervisor engine.
Installing the Supervisor Engine
Warning
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when
servicing. Statement 1034
To prevent ESD damage, handle supervisor module by the carrier edges only.
Caution
Before You Begin
• Verify chassis compatibility and slot restrictions.
◦Catalyst 4503-E—Slot 1 only
◦Catalyst 4506-E—Slot 1 only
◦Catalyst 4507R+E—Slot 3 and slot 4 (redundant supervisor engines supported)
◦Catalyst 4510R+E—Slot 5 and slot 6 (redundant supervisor engines supported)
• Verify that both the supervisor engines (in a redundant configuration) are of the same type.
Procedure
Step 1
Take the necessary precautions, to prevent ESD damage. Wear a grounded ESD wrist strap while handling the modules,
and keep them in ESD-protective bags when they are not installed in a chassis.
Step 2
Ensure that you have enough clearance to accommodate any interface equipment that you will connect directly to the
supervisor module ports.
Step 3
Remove the existing module
• If a switching module filler plate is present, loosen the two captive installation screws that secure the switching-module
filler plate and remove it. Save it for future use.
• If you are removing an existing supervisor engine, see
In a redundant configuration, if you are replacing both supervisors with a different model, remove both supervisor
Note
engines before installing either one of the new models.
Removing the Supervisor Engine, on page
12.
13