ActronAir Cascade 2 Series Instrukcja obsługi - Strona 9

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Centrale wentylacyjne ActronAir Cascade 2 Series. ActronAir Cascade 2 Series 16 stron. Four way cassette

Owner's Manual
Step 3. Remove the air fi lter.
Step 4. Clean the air fi lter by vacuuming the surface or washing it with warm and mild detergent.
Step 5. Rinse the fi lter with clean water and allow it to air-dry. DO NOT let the fi lter dry in direct sunlight.
Step 6. Reinstall the fi lter.
Step 7. Ensure the cable from the display panel to the control box is not loose and not obstructing the grill.
Step 8. Lock the grille by sliding the two tabs outwards simulataneously.
Preparation For Periods of Non-Use
If you plan to not use your air conditioner for an extended period of time, do the following:
• Run the appliance on FAN mode for 12 hours in a warm room to dry all its components. Presence of moisture for a long
period of time may lead to mold formation.
• Turn off the appliance and turn off power via the main power isolator.
• Clean the air fi lter according to the instructions in the previous section. Reinstall the clean, dry fi lter before storing.
• Remove the batteries from the remote control (if remote control is used).
Maintenance – Pre-Season Inspection
After long periods of non-use, or before periods of frequent use, do the following:
• Use a dry cloth to wipe off the dust accumulated on the rear air intake grille in order to avoid the dust being dispersed
from the indoor unit.
• Check that the air fi lter is installed.
• Check if the air outlet or inlet is blocked after the air conditioner has not been used for a long time.
• Turn on the main power isolator at least 12 hours prior to operating the unit.
CAUTION
• Any unit repairs, maintenance and cleaning of outdoor unit should be performed by qualifi ed HVAC technician.
• Filter cleaning can and should be regularly performed by product owner as required.
WARNING
• If the refrigerant leaks, turn off the air conditioner and any combustible heating devices, ventilate the room and call your
HVAC technician immediately. Refrigerant can be toxic. DO NOT use the air conditioner until the leak is repaired.
• When the air conditioner is installed in a small room, measures must be taken to prevent the refrigerant concentration
from exceeding the safety limit in the event of refrigerant leakage. Concentrated refrigerant causes a severe health and
safety threat.
Owner's Manual - Cascade Series 2
Doc. No. 9590-4016 Ver. 2 220616
Four-Way Cassette
9