Również dla Siemens SX Series: Instrukcje obsługi (38 strony), Instrukcja obsługi (38 strony), Instrukcja obsługi (42 strony), Instrukcja obsługi (42 strony), Instrukcja obsługi (44 strony), Instrukcja obsługi (44 strony), Instrukcja obsługi (42 strony), Instrukcja obsługi (48 strony), Instrukcja obsługi (40 strony), Instrukcja obsługi (42 strony), Instrukcja obsługi (44 strony), Instrukcja obsługi (40 strony)

Siemens SX Series Instrukcja obsługi
en
Fault, what to do?

Fault table

Fault
"Check water supply"
display 8 lights up.
Error code ":‹ˆ is lit.
Error code ":‚ƒ is lit.
Fault code ":‚... is lit.
Fault code ":‚† is lit.
Fault code ":‚‡ is lit.
Error code ":ƒƒ is lit.
Error code ":ƒ... is lit.
32
Cause
Supply hose kinked.
Tap turned off.
Tap jammed or calcified.
Filter in the water supply blocked. Switch off the appliance and pull out the
Intake opening (on right inside of
appliance) covered by utensils.
Heating element calcified or
soiled.
Water protection system
activated.
Constant water inflow.
Filters 1Z are soiled or
blocked.
Waste-water hose kinked or
blocked.
Siphon connection still sealed.
Cover on the waste water pump
loose.
Remedial action
Install supply hose without kinks.
Turn the tap on.
Turn the tap on.
Flow rate must be min. 10 l/min. when
water supply is open.
mains plug. Turn off the tap. Unscrew water
connection.
Clean filter in the supply hose. Screw water
connection on again. Check for leaks.
Reconnect power supply. Switch on the
appliance.
Arrange utensils so that the intake opening
is not obstructed.
Clean appliance with dishwasher cleaning
agent or descaler. Operate the dishwasher
with water softening system and check the
setting (see chapter "Water softening
system/Special salt").
Turn off tap.
Call customer service and mention the fault
code.
Clean filters.
(see "Cleaning and maintenance").
Install hose without kinks, remove any
residue.
Check connection to siphon and open if
required.
Lock cover correctly.
(See "Waste water pump")