SYSTEM WIRING DIAGRAM
This drawing remains the intellectual property of Actron Engineering Pty Ltd.
Reproduction, modification and/or distribution are prohibited without written consent.
INDOOR FAN (IF)
INTERNAL AUTO RESET
OVERLOAD PROTECTION
ECM
CONTROL
MODULE
FERRITE
EMC-1
E
N
A
PCB JUMPER PIN
POSITION TABLES
PCB Model: QUEIB
Jumper Pin
A/C Model
Position
ERQ2-14AS
A
B
ERQ3-17AS
C
ERQ4-19AS
D
N/A
E
N/A
FIELD WIRING BY INSTALLER -
CABLE MUST BE 2 CORE 7/0.30 SHIELDED
TWISTED PAIR DATA CABLE WITH SCREEN
WIRE REMOVED ON INDOOR UNIT & SCREEN
FOIL CLAMPED TO P-CLIP ON OUTDOOR UNIT
D
Rev.
C
DESIGNS AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Page 12 of 20
Base
R
Model No:
Description:
Drawn:
Approved:
IF-1
1
EC
FERRITE
ADDED 'G' TERMINAL TO QUEIB
Description
ORIGINAL
Variation Code:
VARIOUS
QUE-SERIES
INDOOR BOARD WITH 2 TOUCH CONTROLLERS
Date:
05-09-2016
RL
JL
23-07-2020
Date:
INDOOR
COIL IN
SENSOR
MANUAL FOR WIRING INSTRUCTIONS
POWER
& DATA
(YELLOW
CAT5E
CABLE)
WiFi
RF
REMOTE
SENSOR 1
240V
QUEIB
LOG
MAINS
DATA
MODULATION
ZONING
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
8
7
6
5
4
3
2
TO ZONE 2 - 8
FIELD WIRING
RJ45 SOCKETS FOR ACTRON AIR
CAT5E SPEC CABLES ONLY
REFER TO QUE CONTROL SYSTEM
INSTALLATION & COMMISSIONING
MANUAL FOR ALL AVAILABLE
CONFIGURATIONS
Installation & Commissioning Guide - ESP Platinum ID Split Ducted Units
Variation:
PLATINUM QUE
Drawing No:
WD2011
MAINTAIN TWISTED
PAIR UNTIL TERMINAL
ON QUEIB
CUT OFF
SCREEN WIRE
IMPORTANT
THIS INSTRUCTION WILL
APPLY WHEN USING
COIL UNIT. (ARV*-**AS & FRQ*-**AS)
COIL SENSOR IS LOCATED IN COIL
SECTION (ARV*-**AS). DURING
INSTALLATION, YOU
THE SENSOR TO THE P.C. BOARD ON
THE FAN SECTION OF INDOOR
UNIT (FRQ*-**AS).
SEE JUMPER PIN POSITION
TABLES FOR CORRECT SETTING
8Z-VAQ DATA CABLE
(GREEN CAT5E CABLE)
FIELD WIRING BY
INSTALLER
REFER TO QUE CONTROL SYSTEM
INSTALLATION & COMMISSIONING
POWER
ONLY
(YELLOW
CAT5E
CABLE)
WiFi
RF
RF
RF
ZONE
CONTROL 1
OPTIONAL WIRED
CONNECTION
- POWER ONLY
ZONE
1
ZONE
MOTOR
3322
PCR
Doc. Part No. 0525-052 Rev. 5 200928
Revision
Size:
A5
D
ONLY
SPLIT
FAN
MUST
CONNECT
RL
23-07-2020
By
Date