Ricoh 4510 Instrukcja wymiany - Strona 2
Przeglądaj online lub pobierz pdf Instrukcja wymiany dla Akcesoria do drukarek Ricoh 4510. Ricoh 4510 2 stron. Printer hard disk
Również dla Ricoh 4510: Instrukcja instalacji (4 strony)
Hold the green handle ( ), and slide out the development
Align the new development unit with the rail in the printer.
unit ( ). Put the used development unit in the disposal
Slide the development unit into the printer until it makes a
bag.
click as it locks into place.
ZFCM060J
Important
At the right side of the printer, remove the tape on the left
After removing the development unit, put the unit in the
and right sides of the black sheet, and then pull out the
disposal bag. Be careful not to tilt or shake the unit, otherwise,
sheet using both hands.
toner might scatter.
Important
Take the new development unit from the Type 4510A box.
Do not toucth the green part protected by the black sheet.
Before taking the development unit from the box, be sure to read
the "Removing the Development Unit from the Box" sheet in the
Type 4510A box and follow the instructions.
Important
After taking the new development unit from the box, be careful
not to shake or jar the unit.
Remove the tape with the red tag ( ) and the transparent
tape ( ).
Important
Leave the right cover open, and go to " REPLACING THE FUSING
UNIT".
While pulling out the tape, keep the development unit
horizontal, as shown in the illustration. Tilting or shaking
the unit might cause the toner to scatter.
Do not remove the black sheet until you finish installing the
unit. The black sheet is used to protect the green part of the
development unit.
ZFCM080J
REPLACING THE FUSING UNIT
CAUTION
The fusing unit becomes very hot. When installing the new fusing
unit, turn off the printer and wait for about 30 minutes. After waiting,
install the new fusing unit. Not waiting for the unit to cool down can
result in a burn injury.
Be sure to wait 30 minutes after turning off the printer,
and confirm that it is cool before continuing.
Pull out the standard paper tray (Tray 1), and take the
screwdriver ( ) from the tray.
ZFCM070J
Remove the screw inside the front cover ( ) by turning it
counterclockwise to release the fusing unit.
TAPM090E
ZFCM090E
Important
When removing the screw, press the screwdriver onto the screw
until it makes an audible click as it pops into place.
TAPP761E
Note
You need the screw to lock the new fusing unit afterwards.
Hold the blue knob, and slowly pull the fusing unit out until
Lock the fusing unit in place with the screw you removed
the whole of the green handle is visible.
in step
.
ZFCM100E
There is the green lever ( ) on the left side of the fusing
Note
unit. While pressing the green lever to the left, slide the
Be sure to return the screwdriver to the paper tray after using
fusing unit out slowly with rasing the green handle and
it.
holding it.
Close the right cover.
ZFCM110E
Take the new fusing unit from the Type 4510B box and
remove the plastic bag.
Important
Do not force the right cover to close. If you cannot close it
easily, confirm that the development unit and the fusing unit
are installed correctly, and that the transfer unit is locked
Remove the two pins with red tag (
), the three
correctly.
transparent tapes ( ) and the desiccant ( ).
ZFCM140J
Note
There is another transparent tape at the bottom of the fusing
unit, make sure to remove the transparent tape.
Place the green handle in the fusing unit. Hold the new
fusing unit with both hands, and keep the unit horizontal.
Align the unit with the rail in the printer ( ), and then
slide the fusing unit into the printer until it stops.
ZFCM120E
Close the duplex unit ( ), and then close the bypass tray
( ).
ZFCM130E
Close the front cover.
Take the gloves off.
ZFCH192E
Turn the printer's power switch on.
Note
The first time you turn the printer on after installation or after
replacing the photoconductor unit, it will make several loud
noises. This is due to the photoconductor unit initializing and
is perfectly normal.
Confirm that the "Change Maint.Kit" message on the
operation panel has cleared.
Replacing the maintenance kit is finished.
Copyright© 2001 G790-8610
Printed in China
UE USA