For more information on troubleshooting an overtemperature condition in your router, see the
Note
"Troubleshooting the Cooling Subsystem" section on page
Table 1-17
the power thresholds for the normal, warning, and critical (power supply-monitored) levels.
Table 1-17 Typical Processor-Monitored Temperature Thresholds
Parameter
Core
Chassis inlet
Chassis outlet 1
Chassis outlet 2
Note
If the system reports temperatures in the critical range, you must manually shut down the router. The
processor cannot shut down the router automatically.
Table 1-18 Typical Power Supply-Monitored Voltage Thresholds
Parameter
+2.5V
+3.3V
+5.15V
+12.3V
+12.3V
–12.5V
Displaying Environmental Status Reports
Cisco 7100 series VPN routers display warning messages on the console if chassis interface-monitored
parameters exceed a desired threshold. You can also retrieve and display environmental status reports
with the show environment, show environment all, show environment last, and show environment
table commands. Parameters are measured and reporting functions are updated every 60 seconds. A brief
description of each of these commands follows.
Caution
To prevent overheating the chassis, ensure that your system is drawing cool inlet air. Overtemperature
conditions can occur if the system is drawing in the exhaust air of other equipment. Ensure adequate
clearance around the sides of the chassis so that cooling air can flow through the chassis interior
unimpeded and exhaust air exits the chassis and is not drawn into the inlet vent of other device.
Cisco 7100 Series VPN Router Installation and Configuration Guide
1-40
lists the typical temperature thresholds for each network processor type, and
High Warning
120°F (49°C)
109°F (43°C)
114°F (46°C)
116°F (47°C)
Low Critical
+2.35V
+3.11V
+4.88
+11.53
+11.53
–10.20V
5-6.
High Critical
129°F (54°C)
118°F (48°C)
123°F (51°C)
125°F (52°C)
Low Warning
High Warning
+2.39V
+2.69V
+3.19V
+3.39V
+5.00
+5.23
+11.77
+12.76
+11.77
+12.76
–11.24V
–13.71V
Chapter 1
Overview
Table 1-18
lists
High Critical
+2.72V
+3.47V
+5.39
+13.05
+13.05
–14.33V
78-6341-03