12
3
Replacing Assembly Units
3.6
Replacing the Cam Plate and the Locking Lever
1
Fig. 11
Replacing the cam plate
Remove covers and centering panels.
Loosen two screws (8) and remove the plate (7).
Loosen two screws (1) and pull the winder plate (4) with the cam plate (3) and the transport module (6) out of the
housing.
Pull the cam plate (3) from the pins (5).
Set the new cam plate onto the pins (5).
Fig. 12
Replacing the locking lever
Pull the locking lever (10) from the pin (9).
Mount the new locking lever.
Push the winder plate (4) with the cam plate (3) and the transport module (4) into the housing and mount the
winder plate with two screws to the gear wheel (2).
Mount the plate (7).
Mount the centering panels and the covers.
2
9
10
3
4
5
6
12
7
8