3-3. Connection Setting on RCP-920/921

Enter the Engineer Mode for setting.
For details of the menu operation block, menu operation method and setting method in Engineer Mode, refer to the Opera-
tion Manual.

3-3-1. SETTING Menu

Menu display method
1. Press the Paint adjustment block [ENTER] button to display the top screen of the Paint menu.
2. Keep pressing the [ENTER] button for more than 1 second to display the RCP Confi guration menu.
3. Switch the setting screen and adjustment screen with the ▲/▼ key of the Paint adjustment block to display the desired
page.

3-3-2. CNS Setting Menu

< C N S
S E T T I N G >
C N S
M O D E : L E G A C Y
M A S T E R
I P
0 .
T A R G E T
I P
0 .
< C N S
S E T T I N G >
C N S
M O D E : B R I D G E
C O N N E C T : S E M I - A T
M A S T E R
I P
0 .
T A R G E T
I P
1 9 2 . 1 6 8 .
Camera Network System
S E T
A D D R
0 .
0 .
0
A D D R
0 .
0 .
0
S E T
A D D R
0 .
0 .
0
A D D R
0 . 1 0 1
Item
Function
CNS MODE Camera Network System (CNS) connection setting
LEGACY : Connection using the conventional
CCA cable
BRIDGE : One-to-one connection mode
MCS :
Multiple unit connection mode
When the CNS MODE is set to "LEGACY"
Item
Function
MASTER IP ADDR
Setting is not required
TARGET IP ADDR
Setting is not required
When the CNS MODE is set to "BRIDGE"
Item
Function
CONNECT Bridge mode operation setting
ACTIVE : The settings are performed from one's
own side
PASSIVE : Awaits connection from the Target
equipment
SEMI-AT : Active or Passive is switched depending
on the connection environment
MASTER
Setting is not required
IP ADDR
TARGET
Set IP address of the connection Target
IP ADDR
*1 : Active when a single unit of RCP is used. Passive when connected to
CCU/HDCU or camera with the CCA cable.
*2 : Setting is not required in the Passive mode.
*1
*2
3-5 (E)