HCD-EP515
Ver 1.2 2003. 07
MAIN
POWER
Ref. No.
Ref. No.
Part No.
Part No.
Description
Description
* CN901
1-564-509-11 PLUG, CONNECTOR 6P
* CN902
1-691-756-11 PIN, CONNECTOR (PC BOARD) 2P
< DIODE >
D906
8-719-991-33 DIODE 1SS133T-77
D907
8-719-063-79 DIODE 1N4002B
D908
8-719-063-79 DIODE 1N4002B
D909
8-719-063-79 DIODE 1N4002B
D910
8-719-063-79 DIODE 1N4002B
D911
8-719-063-79 DIODE 1N4002B
D912
8-719-063-79 DIODE 1N4002B
D913
8-719-063-79 DIODE 1N4002B
D914
8-719-063-79 DIODE 1N4002B
D916
8-719-902-17 DIODE 1N5401
D917
8-719-902-17 DIODE 1N5401
D918
8-719-902-17 DIODE 1N5401
D919
8-719-902-17 DIODE 1N5401
D920
8-719-991-33 DIODE 1SS133T-77
D921
8-719-991-33 DIODE 1SS133T-77
< LINE FILTER >
LF901
1-402-663-11 TRANSFORMER, LINE FILTER (LFT)
< RESISTOR >
R901
1-249-437-11 CARBON
R902
1-249-437-11 CARBON
0 R911
1-219-237-51 CARBON
< RELAY >
0 RY901
1-755-276-11 RELAY, POWER
< TRANSFORMER >
0 T901
1-443-041-11 TRANSFORMER, POWER (KR)
0 T901
1-439-781-11 TRANSFORMER, POWER (US, CND)
0 T901
1-439-779-11 TRANSFORMER, POWER (AEP, UK)
************************************************************
1-688-191-11 REGULATOR BOARD
****************
< IC >
IC305
8-759-347-18 IC KIA7809PI
************************************************************
40
REGULATOR
Remarks
Remarks
47K
5%
1/4W
47K
5%
1/4W
3.3M
5%
1/2W
(US, CND)
Ref. No.
Part No.
Description
MISCELLANEOUS
**************
0 8
1-696-169-12 CORD, POWER (KR)
0 8
1-696-169-12 CORD, POWER
0 8
1-696-169-12 CORD, POWER (AEP, UK)
11
1-693-619-11 TUNER (FM/AM) (AEP,UK)
11
1-693-622-11 TUNER (KR)
11
1-693-624-11 TUNER (FM/AM) (US,CND)
65
1-796-351-51 MECHANISM, SINGLE CASSETTE
106
1-757-055-11 WIRE, PARALLEL (FFC) (16 CORE)
0 602
8-820-221-01 OPTICAL PICK-UP KSM-213EDP
S800
1-692-960-11 SWITCH, PUSH (1 KEY) (OPEN)
0 T902
1-439-769-11 TRANSFORMER, POWER (KR)
0 T902
1-439-778-11 TRANSFORMER, POWER (AEP, UK)
0 T902
1-439-780-11 TRANSFORMER, POWER (US, CND)
The components identified by
mark 0 or dotted line with mark
0 are critical for safety.
Replace only with part number
specified.
Remarks
Les composants identifiés par
une marque 0 sont critiques
pour la sécurité.
Ne les remplacer que par une
pièce portant le numéro spécifié.