Digitrax SoundFX SDXH186MT Podręcznik - Strona 7
Przeglądaj online lub pobierz pdf Podręcznik dla Kontroler Digitrax SoundFX SDXH186MT. Digitrax SoundFX SDXH186MT 16 stron. Complete train control
Scaleable Speed Stabilization (Back EMF) intensity, or droop, is
controlled by CV57. The factory setting for this feature is 006 which is
suitable for most locos. You can adjust this value in the range of 000
for OFF to 015 for the maximum effect. Consult your Digitrax Decoder
Manual for info about CVs 55 & 56 and their effects on scaleable speed
stabilization. The factory setting for both CV55 & CV56 is 000.
Logic Level or 12v 21 pin function outputs CV64
The DH166MT can be configured via CV64 for compatibility with either
Logic Level or 12 Volt function formats for outputs F3,F4,F5, and F6. By
default CV64 is set to a value of 0 for Logic Level compatibility. This is
the most common configuration for locomotives using the 21MTC inter-
face. Setting CV64 to a value of 64 will set a bit for function compatibility
to 12v format comparable to that of F0, F1, and F2 .
®
Digitrax SoundFX
System
Digitrax SoundFX lets you make your locos sound in scale like the real
thing! The SoundFX sound CVs in the range of CV140 to CV256 let you
customize your decoder without having to reprogram or change the in-
stalled sound scheme.
Diesel Notching CV132 and 155
Sound CV155 is provided to select Diesel engine "notching" modes. The
default of CV155= 00 provides "automatic notching" that changes the
diesel RPM settings at 8 distinct throttle speeds that are controlled by
Sound CV132. Sound CV155=01 selects "semi-automatic notching" mode
that allows F6 ON to increase the notch from the current throttle setting
and F7 ON to decrease back towards the lowest current throttle notch
setting. Sound CV155=02 selects "manual notching" mode that allows F6
ON to increase the notch setting and F7 ON to decrease the notch setting
irrespective of the throttle setting, which controls just the motor speed.
Steam Chuff / Cam Configuration and Gear Rotation
Trim CV133 and 134
CV133 controls the Steam Chuff / Cam configuration in the decoder it
allows you to get the value of the CV equal to the diameter of the driver in
inches from 1-27 or to set the CV to 128 to enable the external cam lead.
CV134 controls the gear rotation trim where a value of 32 equals a 100%
ratio.
© 2017 Digitrax, Inc.
— 7 —
www.digitrax.com