Fimer R25 Series Podręcznik - Strona 10

Przeglądaj online lub pobierz pdf Podręcznik dla Modem Fimer R25 Series. Fimer R25 Series 12 stron. Grid connected pv inverter internal and external gsm modem user guide for single-phase inverter
Również dla Fimer R25 Series: Podręcznik użytkownika (16 strony)

Fimer R25 Series Podręcznik
________________________________________________________________________________

8.1.2 Using HyperTerminal

Read out the annual sensor energy logger using HyperTerminal and command /8. Entering
command /9 displays the actual yield and the sensor yield at the same time..

9 Alarm

If the inverter detects a yield variation, it continues to function but an acoustic and a visual alarm
signal are output.
The LCD display switches on. The word "Alarm" and the cause of the alarm are displayed
alternately in the third line of the basic (start) screen. The LED on the cover of the inverter flashes
red and green alternately.
The alarm horn integrated in the inverter emits an intermittent alarm tone. It sounds for half a
second every second. The alarm horn can be switched off by pressing any button.
Switching off the alarm.
Parameter number 279: Alarm configuration
Menu
Short Description
Default Value
To switch the alarm off
_____________________________________________________________________________
8
Installation Monitoring
CFGW
383
Set the parameter to 0.